NSF/ANSI 42 covers aesthetic effects such as chlorine taste and odor, NSF/ANSI 53 covers health effects such as lead or cyst reduction, NSF/ANSI 58 covers reverse osmosis systems, and NSF/ANSI 401 covers a short list of emerging compounds and microplastics. None of these numbers means a filter reduces everything in its standard. Each certified product carries a list of specific reduction claims, and the only way to know what a filter does is to read that list in the certifier’s public directory, matched to a test of your own water.
This article explains what each standard covers, why “NSF 42 vs 53” is the wrong comparison to stop at, and how to look up a model claim by claim. Every count below comes from NSF’s public listings, which NSF states were current as of November 21, 2026, and every rule comes from an EPA, CDC or Mississippi State Department of Health (MSDH) page checked on November 22, 2026.
What NSF/ANSI 42, 53, 58 and 401 each cover
Each standard is a test method for one kind of product or one family of claims, and the certifier lists products standard by standard. The titles below are the ones NSF uses on its drinking water treatment unit search page, where anyone can search by manufacturer, model, standard or claim.
| Standard | NSF listing title | Typical claims on the listing |
|---|---|---|
| NSF/ANSI 42 | Drinking Water Treatment Units, Aesthetic Effects | Chlorine reduction, chloramine reduction, taste and odor reduction, nominal particulate reduction (by class), zinc reduction |
| NSF/ANSI 53 | Drinking Water Treatment Units, Health Effects | Lead, cyst, mercury, PFOA, PFOS, total PFAS, trihalomethanes (TTHM), VOC, microcystin, turbidity and dozens of named chemicals |
| NSF/ANSI 58 | Reverse Osmosis Drinking Water Treatment Systems | TDS, lead, copper, fluoride, nitrate and nitrite, arsenic (pentavalent), barium, radium, cyst and others |
| NSF/ANSI 401 | Drinking Water Treatment Units, Emerging Compounds/Incidental Contaminants | Fifteen named compounds (for example ibuprofen, bisphenol A, DEET, estrone) and microplastics |
| NSF/ANSI 44 | Cation Exchange Water Softeners | Hardness reduction, barium, radium 226/228, efficiency rating |
| NSF/ANSI 55 | Ultraviolet Microbiological Water Treatment Systems | Disinfection performance, Class A or Class B |
| NSF/ANSI 62 | Drinking Water Distillation Systems | Distillation claims |
A few plain definitions help before going further:
- A standard is the written test method and its pass criteria.
- Certification means an accredited third-party body evaluated the product against that method and lists it publicly.
- A claim is one contaminant or effect the product passed, such as “Lead Reduction”. Products are certified claim by claim.
- A listing is the certifier’s public directory entry for the product, with its claims, rated capacity and replacement parts.
The CDC’s page on choosing home water filters, reviewed November 10, 2026, describes the same starting point: “One way to figure out what a water filter removes is to look for an NSF certification on the filter’s label.” The label is where you start. The listing is where you confirm.
NSF 42 vs 53: aesthetic claims versus health claims
The short answer to “NSF 42 vs 53” is that 42 deals with how water tastes, smells and looks, and 53 deals with contaminants that affect health. They are not two grades of the same thing, and one does not contain the other. A filter can be certified to both, to one, or to neither, and its claims under each are listed separately.
What a 42 claim tells you
The claims on NSF’s 42 list are things you notice: chlorine taste and odor, chloramine, particles, zinc. A pitcher or faucet filter with only 42 claims can make water taste better without having been tested for lead or any other health contaminant. That is a fair product for a fair purpose, as long as nobody reads the mark as more than it is.
Two 42 claims are easy to confuse. Chlorine reduction and chloramine reduction are separate claims, and the difference matters to anyone whose utility uses chloramine. In NSF’s 42 listing current as of November 21, 2026, 5,621 products carried a chlorine reduction claim and 221 carried a chloramine reduction claim. Far fewer products on that listing had been tested for chloramine than for chlorine.
What a 53 claim tells you
NSF’s claim list for 53 runs from 1,1,1-trichloroethane to xylenes, with lead, cysts, mercury, PFOA and PFOS, total PFAS, microcystin and trihalomethanes in between. A product listed under 53 is certified only for the claims printed on its own row. In NSF’s 53 listing on November 21, 2026, 1,026 products carried a lead reduction claim and 57 carried PFOA and PFOS reduction claims. A filter certified under 53 for lead may have no PFAS claim at all.
Why the comparison matters for lead
EPA’s June 2024 consumer tool for filters certified to reduce lead asks for both standards at once. It says certification bodies require “their mark and a statement indicating testing against NSF/ANSI Standard 53 along with a claim of lead reduction,” and recommends that you “also look for filters tested against NSF/ANSI Standard 42 for particulate reduction (Class I).” The tool describes filters evaluated for lead reduction “to 5 parts per billion (ppb) or less.” So for lead, the useful answer to “42 or 53” is a 53 lead claim plus a 42 Class I particulate claim, read on the same product.
What the box says, and what it leaves out
The table below turns the most common package wording into what you can and cannot conclude from it. In every row, the listing is the tiebreaker.
| The package says | What you can conclude | What you cannot conclude |
|---|---|---|
| “Certified to NSF/ANSI 42” | The product passed at least one aesthetic claim, such as chlorine or particulate reduction | That it reduces chloramine, lead, PFAS or any health contaminant |
| “Certified to NSF/ANSI 53” | The product passed at least one claim on the 53 list, which is almost entirely health effects claims | Which one: lead, cysts, PFOA and PFOS, TTHM or something else |
| “Certified to NSF/ANSI 42 and 53 for the claims on the performance data sheet” | The claims are listed on the data sheet and in the directory | Anything not on that sheet |
| “Certified to NSF/ANSI 58” | A reverse osmosis system passed at least one claim, often TDS reduction | That it carries a lead, nitrate, arsenic or PFAS claim |
| “Certified to NSF/ANSI 401” | The product passed one or more of 16 specific claims | That it reduces lead or PFAS |
| “Lead free” or a [Pb], 61 or 372 mark | The product’s wetted materials meet the lead content definition | That it removes lead from water |
Certification is claim by claim, not standard by standard
The single most useful thing to know about filter certification is that the standard number on the box is a family name, not a promise. Each product row in a listing names the exact contaminants it passed, and everything not named is outside the certification. The chart below shows how unevenly claims are spread across NSF’s listings on one date.
Three things in that chart change how you shop.
- Chlorine is common, chloramine is not. A carbon filter with a 42 chlorine claim has not been shown to reduce chloramine unless it also lists that claim.
- Lead claims are common under 53 but much rarer under 58. On NSF’s 58 listing, 147 reverse osmosis systems carried a lead reduction claim out of 465 listed systems. Many listed RO systems carried a TDS reduction claim and nothing else.
- PFAS claims are rare. Only 57 products in NSF’s 53 listing carried PFOA and PFOS claims, and 49 carried a total PFAS claim. NSF’s claim list for 58 had no PFOA or PFOS entry at all on that date. An RO system could still carry a PFAS claim from another accredited certifier, which is why you check that certifier’s directory.
Claim groups that cover many chemicals
Some claims stand for a group. NSF’s listing footnote explains that “a VOC reduction claim by the manufacturer means the system reduces the concentration of all of the following contaminants,” followed by a list of more than 50 chemicals that includes total trihalomethanes, benzene, atrazine and tetrachloroethylene. A VOC claim is therefore broad, while a single TTHM claim is narrow. Read which one the product carries.
Claims with conditions attached
Some claims only hold under stated conditions. On NSF’s 58 listing, arsenic claims are for pentavalent arsenic, and the footnote says such a product “is intended for use only on water supplies that have been shown to be at or below the referenced concentration and valency of arsenic.” That means a lab test has to show both the arsenic level and its form before the claim applies to your water. The treatment selector flags the same point for wells: arsenic III usually needs oxidation first.
Claims that do not exist yet
The list itself tells you what nobody is certified for. JXN Water’s 2025 report lists haloacetic acids (HAA5) among its disinfection byproducts, but NSF’s claim list for 53 and 58, as shown on its search page on November 22, 2026, has no claim named for HAA5 or haloacetic acids as a group. If a result on your report has no matching claim, a certification cannot answer the question, and the conversation moves to the laboratory and to a treatment engineer.
How to check a filter’s claims in a certifier’s listing
You can confirm any certified filter in about ten minutes with the model number and a browser. EPA’s PFAS filter page, updated November 12, 2026, names five ANSI-accredited certification bodies with public product directories: CSA Group, IAPMO R&T, NSF, UL and WQA. ANSI is the American National Standards Institute. A filter certified by any of the five can carry an NSF/ANSI standard number, so a product without the NSF logo may still be properly certified, by another body, to the same standard.
Step by step
- Find the certifier’s mark on the box. EPA’s April 2024 fact sheet says each certification body “has a registered trademark that is used on certified products.” Note which body it is.
- Write down the exact model and the replacement cartridge number. Listings are by model. A housing and its cartridge are often listed as a pair.
- Open that certifier’s directory. EPA’s PFAS page links all five. NSF’s is the drinking water treatment unit search.
- Search by manufacturer or model, not by a store’s product name. On NSF’s page, enter at least three letters of the manufacturer or model.
- Read the product’s own row. Note the standard heading above it, the product type, the replacement element, the rated service cycle in gallons, the flow rate in gallons per minute and every claim.
- Compare the claims with your test results, one contaminant at a time. Anything on your report that is not a listed claim is not covered.
- Check the performance data sheet that comes with the product. EPA’s lead tool says claims “not included on the filter packaging can typically be found on the performance data sheet” inside the package, in the certifier’s directory or on the maker’s website.
- If in doubt, ask the certifier. EPA’s fact sheet says “If still in doubt, you can contact the certification body directly from their websites.” NSF’s own listing pages ask users to contact NSF to confirm the status of any listing.
Wording that is not a certification you can check
Some packages use language that sounds like certification but cannot be confirmed in any directory. EPA’s fact sheet describes certification as something done “by an independent entity,” and its PFAS page says such certifications “verify the effectiveness of the filters and accuracy of the contaminant reduction claims.” Use that as the test: if an accredited body’s directory does not show the model with the claim, treat the claim as unverified.
- “Tested to NSF standards” or “meets NSF standards.” Look for the certifier’s mark and a directory entry. Without both, you have the seller’s word, not a certification.
- “Uses NSF certified media” or a certified component. NSF’s search page has separate product types for components, such as carbon blocks, membranes and filter cartridges, and its 58 listing notes that “All Replacement Modules Are Components.” A certified membrane inside an uncertified housing is not a certified system. Check that the system you are buying is listed as a system.
- A reduction percentage with no listing. A number such as “removes 99 percent” means little without the standard, the claim and the directory entry behind it.
- A claim about a contaminant that has no listed claim. If you cannot find the contaminant on the certifier’s claim list for any standard, no certification covers it.
- A mark from an unknown body. EPA names five accredited bodies for drinking water filters: CSA Group, IAPMO R&T, NSF, UL and WQA. Ask a seller who cites another body to show where that body’s directory lists the product.
Reading one listing row
A listing row is short, and every column matters. The diagram below shows the columns NSF uses for 42 and 53 listings, filled in for a made-up product.
Example (fictional). A household of four in Jackson buys a faucet-mounted filter labeled “NSF/ANSI 42 and 53”. In the certifier’s directory, its row lists chlorine reduction and Class I particulate reduction under 42, and lead and cyst reduction under 53, with a 750-gallon service cycle and a flow of 0.5 gallons per minute. The family wanted two things: less disinfectant taste and lower lead risk at the kitchen tap. The lead claim fits the second goal. For the first, the listing shows chlorine reduction but not chloramine reduction, and the family’s utility report names chloramine as the disinfectant. The filter is a reasonable lead choice, but it is not certified for the taste problem they set out to fix.
Service cycle, flow rate and the replacement cartridge
A certification holds only while the product is used within the limits it was tested at. The listing gives those limits, and they decide when a cartridge has to come out.
Service cycle and capacity
For 42, 53 and 401 products, NSF lists a service cycle in gallons for the replacement element. That is the volume the product was tested to. Past it, the product is outside what was tested. NSF’s footnote adds that “claims of capacity or rated service cycle are not applicable for mechanical filtration,” so some particulate-only products show no gallon rating.
EPA’s fact sheet is blunt about upkeep: “Filters are only effective if they are maintained according to the manufacturer’s instructions.” EPA’s lead page adds that “using the cartridge after it has expired can make it less effective at removing lead,” and says not to run hot water through the filter.
Example (fictional). A kitchen filter is rated for 750 gallons, and the household draws about 3 gallons a day for drinking and cooking. The gallon rating runs out after 250 days. The manufacturer also sets a 6-month limit, which arrives first, at about 182 days. The cartridge is replaced every 182 days, about twice a year. These are the default inputs and outputs of the filter life calculator, which lets you enter your own listing figures.
Flow rate
The listing also gives a flow rate in gallons per minute. The listed flow is part of the conditions the product was certified under, so it belongs in any comparison. For whole-building and commercial equipment, the listed flow has to be at least the building’s design flow, which is how a specification should state it.
Reverse osmosis and UV list different numbers
NSF’s 58 listing shows a daily production rate in gallons per day rather than a service cycle, and its heading notes that “All Replacement Modules Are Components.” The membrane and the prefilters each have their own part numbers. NSF’s 55 listing for ultraviolet systems shows a replacement bulb and a flow rate. For UV, the lamp is the consumable, and the class (A or B) is part of the claim.
Lead content of the product versus lead reduction
Many rows carry a [Pb] symbol. NSF’s footnote says such a product was “evaluated and determined to possess” a weighted average lead content of 0.25 percent or less and meets the requirements for “lead free” plumbing under the Safe Drinking Water Act and several state laws. That is a statement about the materials the product is made of, not about how much lead it removes. EPA’s lead free marks guide explains the same split for faucets and fittings: NSF/ANSI/CAN 61 and 372 marks show the product meets the lead free definition, which since September 21, 2023 importers and manufacturers must certify. A faucet with a 372 mark does not filter anything.
Matching claims to a water test
A certification answers “what was this product tested to reduce?” Only a water test answers “what is in my water?” The right filter is the overlap between the two lists, and neither list is optional.
Where your results come from
- City water. Your utility’s annual Consumer Confidence Report lists what the system detected across its service area. It does not describe your service line, pipes, faucets or water heater.
- Your own taps. A sample from your kitchen tap, analyzed by a certified laboratory, describes the water you actually drink. EPA says “testing is the only sure way of telling whether there are harmful quantities of lead in your drinking water.”
- A private well. No utility tests it for you. The owner chooses what to test.
The water test reader compares a laboratory report with EPA reference values line by line, and the treatment selector maps one problem at a time to the claim that addresses it.
A Jackson reading of the claim lists
JXN Water’s 2025 Water Quality Report shows how a report points to specific claims. These are the report’s own statements, not a judgment about the water at any tap.
| What the 2025 report says | Claim to look for in a listing |
|---|---|
| Surface water system table lists chloramine as the disinfectant (running annual average 3.0 ppm) | NSF/ANSI 42 chloramine reduction, not only chlorine reduction |
| Maddox Road groundwater system table lists chlorine (running annual average 1.10 ppm) | NSF/ANSI 42 chlorine reduction |
| Surface system: 2025 violations of the TTHM and HAA5 locational running annual averages | NSF/ANSI 53 TTHM reduction or a VOC claim for TTHM; no listed claim is named for HAA5 |
| Surface system lead 90th percentile 4.5 ppb (January to June 2025) and 4.1 ppb (July to December 2025), action level 15 ppb | NSF/ANSI 53 lead reduction, plus 42 Class I particulate, per EPA’s lead tool |
MSDH’s Jackson water system page, which cites tap samples from 2021, recommends that “any child five years of age or younger and any pregnant woman should use filtered water (NSF53 certified filter) or bottled water for drinking and cooking.” Read in light of this article, that recommendation means a filter whose listing shows a lead reduction claim under 53. A 53 listing without a lead claim does not meet the intent. For a fuller reading of Jackson’s report, see is Jackson tap water safe to drink.
Point of use or point of entry
The same claims appear on products of very different sizes. NSF’s search page sorts them by product type: pour-through units, faucet mounts, countertop units, refrigerator filters, units plumbed in to a separate tap, and point-of-entry systems that treat all the water entering a building. The product type changes what a claim protects.
- Point of use treats one tap or appliance. A lead claim on a kitchen unit protects the water drawn from that tap only, which is where most drinking and cooking water comes from.
- Point of entry treats everything after the meter. A chloramine or chlorine claim on a point-of-entry unit changes the water at every tap, shower and appliance, which matters for taste and for some equipment.
- Lead usually belongs at the point of use. Lead can come from a building’s own service line, solder and fixtures, which sit downstream of a point-of-entry unit. EPA’s lead page names “lead pipes, faucets, and fixtures” as the most common sources of lead in drinking water.
Many buildings end up with both: a point-of-entry unit chosen for one set of claims and point-of-use units at drinking taps chosen for another. Each unit is checked against its own listing.
Why taste alone is a poor guide
EPA’s lead page notes that “you cannot see, taste, or smell lead dissolved in water.” A filter that makes water taste better has done its 42 job, and that tells you nothing about a 53 concern. Treatment chosen from taste alone is how people end up with a certification that answers the wrong question.
PFAS, lead and germs: three claims people misread
Three topics are especially easy to misread. Each has an official source that says plainly what certification does and does not show.
PFAS
EPA’s fact sheet says that “as of April 2024, filter certifications focus on removing the chemicals PFOA and PFOS,” and EPA’s PFAS filter page repeats that “the current certification standards for PFAS filters (as of April 2024) do not yet indicate that a filter will remove PFAS down to the levels EPA has now set for a drinking water standard.” EPA tells buyers to look for NSF/ANSI 53 or 58 “for PFAS reduction” and to “check NSF website to see if product treats the type of PFAS you’re trying to remove.” In practice that means:
- Look for PFOA and PFOS claims on the product’s own row, or a total PFAS claim where one is listed.
- Do not read a lead or cyst claim under 53 as a PFAS claim.
- Check the date on any claim against EPA’s current guidance, because standards and rules are both moving.
EPA’s fact sheet also says a filter “may not be useful to you” if PFAS have not been measured in your water or are below federal limits, and that filters cost “as little as $20 or more than $1,000,” not including maintenance. Whether a Mississippi household or business needs one at all is the subject of our separate article on PFAS water filters.
Lead
For lead, EPA’s lead tool sets the most specific bar on this list: a 53 lead reduction claim tested to reduce lead to 5 ppb or less, plus a 42 Class I particulate claim, confirmed in the certifier’s directory. EPA also reminds readers that “boiling water does not remove lead from water.” Keep two lead marks apart:
- Lead reduction (53 or 58): the product reduces lead in the water passing through it.
- [Pb], 61 or 372 marks: the product’s own wetted materials meet the lead free definition.
A lead free faucet and a lead reduction filter do different jobs, and a building may need both.
Bacteria, viruses and cysts
The CDC’s filter page says that most home water filters, such as pitcher or fridge filters, “are not designed to remove germs from your water.” Its list of filters that address Cryptosporidium includes those “certified to NSF standards 53 or 58 for cyst reduction or removal” and those with an absolute pore size of 1 micron or smaller. A cyst claim is not a bacteria or virus claim. The CDC lists reverse osmosis and nanofiltration among filter types that remove viruses, but that is a statement about technologies, not about any certified product’s listing.
That is why a filter does not replace a boil water notice. During a notice, follow the notice and the issuing utility or health department, not the filter label. The boil water notice checklist covers what to do with filters during and after a notice.
Other marks you will see: 44, 55, 62, 177, 401 and ASSE 1087
The same NSF search page lists several other programs. Each one is narrow, and none of them stands in for 53 or 58.
| Program | What NSF lists | Products listed by NSF, November 21, 2026 |
|---|---|---|
| NSF/ANSI 44 | Cation exchange water softeners: hardness, barium, radium, efficiency rating | 313 products, 13 manufacturers |
| NSF/ANSI 55 | UV systems, disinfection performance Class A or Class B | 362 products, 19 manufacturers |
| NSF/ANSI 62 | Distillation systems | No matching products in NSF’s listing on that date |
| NSF/ANSI 177 | Shower filtration systems, aesthetic effects (free available chlorine) | 11 products, 7 manufacturers |
| NSF/ANSI 401 | Fifteen named emerging compounds and microplastics | 1,510 products, 61 manufacturers |
| ASSE 1087 | Commercial and food service water treatment equipment utilizing drinking water | 631 products, 3 manufacturers |
| CSA B483.1 | Drinking water treatment systems | 1,295 products, 57 manufacturers |
NSF/ANSI 401 in practice
A 401 claim is for a specific compound on a fixed list: atenolol, bisphenol A, carbamazepine, DEET, estrone, ibuprofen, linuron, meprobamate, metolachlor, naproxen, nonylphenol, phenytoin, TCEP, TCPP and trimethoprim, plus microplastics. On November 21, 2026, 1,127 products in NSF’s listing carried the microplastics claim. A 401 claim is not a 53 claim, and a refrigerator filter with 401 claims may have no lead claim.
ASSE 1087 for restaurants and commercial equipment
ASSE 1087 is the commercial and food service category on the same NSF site. On November 21, 2026, its entries listed product names and models without a column of reduction claims. If a filter feeds an ice machine, a coffee brewer or a beverage line, check whether it also holds 42 or 53 claims for what your water test shows, and read the equipment maker’s water requirements. The restaurants page covers how this equipment fits a food business.
Example (fictional). A 40-seat cafe on city water plans a new ice machine and an espresso machine. The supplier proposes a commercial filter system that appears in the ASSE 1087 listing. The owner checks the same model in the 42 listing and finds a chlorine reduction claim but no chloramine claim, while the utility’s report names chloramine as the surface system’s disinfectant. The owner asks the supplier for a cartridge that lists chloramine reduction, confirms the flow rate covers both machines running together, and puts the cartridge’s gallon rating into the maintenance log. The ASSE 1087 entry answered whether the equipment belongs in a commercial setting. The 42 listing answered what it does to the water.
Not part of this program: 61, 372 and 350
Plumbing components carry NSF/ANSI/CAN 61 or 372 marks, which concern lead content and leaching from the component itself. Greywater and wastewater reuse units are listed under a different program, NSF/ANSI 350, which on November 21, 2026 named 6 manufacturers and 69 products in Class R (single family) and Class C (multifamily and commercial). Reuse water is non-potable, and a 350 listing says nothing about drinking water. The standards page lists how each of these appears in a specification.
How Maredes uses certifications in a specification
Maredes is a Jackson, Mississippi company that designs compact water filtration and reuse systems for one building at a time. It holds no certifications from NSF, WQA, IAPMO, UL, CSA Group or any other body, and it does not test or certify products. What it does is write certification requirements into every equipment specification and check them against the certifier’s listing.
In practice, a specification line for a drinking water unit names four things:
- The standard and the claim. For example, “certified to NSF/ANSI 53 for lead reduction and NSF/ANSI 42 for chloramine reduction,” not “NSF certified.”
- The listing check. The model and replacement element must appear in an accredited certifier’s directory with those claims on the date of purchase.
- The limits. A listed flow rate at least equal to the design flow, and a service cycle that sets the cartridge schedule.
- The source of the requirement. The laboratory result or utility report line that the claim answers.
The drinking water systems page shows how point-of-use units for kitchens, break rooms and ice machines are specified this way. For a whole building, whole-building filtration applies the same rule to point-of-entry equipment. Every design starts with a water review and a sampling plan, so the claims are chosen from a certified laboratory’s results rather than from a product’s marketing. If you are choosing between technologies first, see reverse osmosis vs carbon filters.
A checklist before you buy or approve a filter
Use this list at the store, on a supplier’s quote, or when a contractor proposes equipment for your building.
- Know what is in your water. Read your utility’s Consumer Confidence Report or your well test, and test your own taps for anything that depends on your plumbing, such as lead.
- List the problems in order. Health concerns first (lead, nitrate, arsenic, PFAS, bacteria), then appearance and taste.
- Write the claim you need next to each problem. Lead reduction under 53, chloramine reduction under 42, and so on. Use the treatment selector if you are unsure which standard holds the claim.
- Identify the certifier from its mark. CSA Group, IAPMO R&T, NSF, UL or WQA.
- Look up the model and its replacement element in that certifier’s directory.
- Tick each claim on the product’s own row. Anything not listed is not certified.
- Check conditions. Arsenic valency, flow rate, service cycle, and whether the claim is for the system or only a component.
- Keep the evidence. Save the listing page, the performance data sheet and the lab report together.
- Plan the replacements. Set the cartridge schedule from the listed gallons and the maker’s time limit, whichever comes first.
- Retest after installation where the concern is a health contaminant, so the result is measured, not assumed.
If you would like this done for a building, with the sampling, the claim-by-claim specification and the listing checks written down, request a water review. More articles on certification, EPA rules and Mississippi water policy are collected in standards and rules.
