Water test result reader
Type in the numbers from your lab report. Each one is placed beside the EPA reference value that applies, and anything above it is flagged.
For: Well owners, homeowners and building managers with a laboratory water report

Result reader
A laboratory report lists numbers, units and detection limits, often without saying what they mean. This reader places each result beside the EPA value that applies and flags anything above it. It is for private well owners, homeowners on city water who ordered a test, and building managers holding a lab report or a utility’s Consumer Confidence Report. Leave blank anything your report does not include.
What it compares
| Result | Reference value | Type |
|---|---|---|
| Lead | 15 ppb (0.015 mg/L); 10 ppb from November 1, 2027 | Action level; EPA’s health goal is zero |
| Copper | 1.3 mg/L | Action level |
| Nitrate as nitrogen | 10 mg/L | Maximum contaminant level |
| Arsenic | 10 ppb (0.010 mg/L) | Maximum contaminant level |
| Fluoride | 4.0 mg/L | Maximum contaminant level; secondary standard 2.0 mg/L |
| Iron | 0.3 mg/L | Secondary standard |
| Manganese | 0.05 mg/L | Secondary standard |
| Total dissolved solids | 500 mg/L | Secondary standard |
| pH | 6.5 to 8.5 | Secondary range |
| Total coliform, E. coli | Present or absent | Any presence is flagged |
Hardness is converted to grains per gallon (mg/L as calcium carbonate divided by 17.1) because EPA sets no health limit for it and softeners are sized in grains. The first row of the result counts how many values are above a reference.
The types matter. Maximum contaminant levels and action levels are enforceable standards for public water systems. Secondary standards are non-mandatory guidelines for taste, odor, color and staining, which EPA does not enforce. An action level is also not a pass mark for one tap: it applies to a water system’s samples, and if more than 10 percent of them exceed it, the system must take additional steps.
The inputs and where to find them
Every number comes from the laboratory report. Check the units on each line before you type:
- ppb and µg/L are the same. 1 ppb equals 0.001 mg/L, so a lead result of 0.003 mg/L is 3 ppb.
- Nitrate may be reported “as N” (nitrogen) or as nitrate itself. The limit here is for nitrate as nitrogen; ask the lab if the report does not say.
- Below detection. A result shown as “less than” a number, or “ND,” means the lab did not find it at that level. Entering the detection limit shows how far below the reference it sits.
- Coliform and E. coli are reported as present or absent, or as a count. Any count above zero is “present.”
The default example
Example (fictional). A fictional laboratory report for a private well shows lead 3 ppb, copper 0.2 mg/L, nitrate 2.1 mg/L, arsenic 1 ppb, fluoride 0.2 mg/L, iron 0.6 mg/L, manganese 0.08 mg/L, total dissolved solids 310 mg/L, hardness 150 mg/L, pH 6.8, and total coliform and E. coli absent. The reader returns: results above a reference value, 2 of the values entered. Iron: 0.600 mg/L: ABOVE 0.3 mg/L (secondary standard). Manganese: 0.080 mg/L: ABOVE 0.05 mg/L (secondary standard). Lead, copper, nitrate, arsenic, fluoride and total dissolved solids are at or below their reference values; hardness is 150 mg/L as CaCO3 (8.8 grains per gallon); pH 6.8 is within the 6.5 to 8.5 secondary range.
Both flags are secondary standards: iron and manganese at these levels are a staining and taste question, not an enforceable limit. The usual treatment is oxidation followed by filtration, which the treatment selector explains.
Reading the result
- Above a secondary standard: a taste, staining or equipment question. Treat it if it bothers you or harms equipment.
- Above a primary standard or action level: retest first with a certified laboratory, then act. For city water, call the utility. For a private well, ask the laboratory and the Mississippi State Department of Health.
- Coliform or E. coli present: for a well, MSDH’s well disinfection procedure and a repeat bacteria test come before any filter. The private well checklist has the steps.
- Lead below the action level: EPA and CDC say “there is no known safe level of lead in a child’s blood,” so a result under 15 ppb is not the same as no lead.
Limits and next steps
This is a screening comparison, not a diagnosis or medical advice. It does not cover PFAS. EPA set limits of 4.0 parts per trillion for PFOA and PFOS in April 2024. On May 18, 2026 it proposed keeping those two, with an option for systems to request two more years (to 2031), and rescinding the limits for PFHxS, PFNA, HFPO-DA and the Hazard Index mixture. EPA’s page described both as proposed rules when checked on November 22, 2026.
Primary standards apply to public water systems. EPA notes that private wells are not regulated under the Safe Drinking Water Act, so a well owner is responsible for their own testing. MSDH tests private wells for bacteria only and publishes a list of certified laboratories for the other tests.
The hardness figure feeds the softener sizing calculator. A water review includes a sampling plan, certified laboratory analysis and every result explained in writing, and standards explains how Maredes specifies treatment equipment by certification.
Start with a water review.
Tell us about the building: what it is, who uses it, where the water comes from and what you would like to change. We reply with questions and a time to walk the building with you.