Maredes homeRequest a water review
Menu

Toilet leaks in apartment buildings: how to find them and what they cost

The reader questionHow much water do toilet leaks waste in a master-metered apartment building, and how do owners find them?

A plain black rubber toilet flapper floats at the waterline while a thin, steady trail of tiny bubbles escapes from beneath it into the clear water.

Toilet leaks can waste as much water in an apartment building as the toilets use to flush. In a 2023 Los Angeles pilot that put leak sensors on 1,198 toilets in eight master-metered affordable housing properties, 51 percent of all toilet water was lost to leaks, even though leak alerts were running the whole time. Owners find these leaks by tracking the master meter at night, dye-testing every tank on a schedule or installing in-line flow sensors, and water is saved only when each leak is repaired within days. At JXN Water’s top combined block, every 1,000 gallons that leaks costs about $26.67 in water and sewer charges.

This guide draws on the Pacific Institute’s published pilot data, EPA WaterSense guidance and the U.S. Department of Energy’s maintenance practices for toilets. It covers why one meter hides leaks, which parts fail, how to find leaks step by step, how to price them on a Jackson bill, sensors versus scheduled audits, and the repair routine that decides whether any of it pays.

How much water do toilet leaks waste in an apartment building?

In the most detailed published multifamily pilot, leaks took slightly more toilet water than flushing did. EPA separately estimates that about 20 percent of toilets leak.

What the Los Angeles pilot measured

The Pacific Institute’s April 2024 report, Saving Water and Money Through Toilet Leak Detection, describes eight properties owned by the Housing Authority of the City of Los Angeles. Each had a single master meter and no dedicated irrigation meter. In March 2023 every toilet in every unit and common area received a sensor that reported flushes, leaks and alerts to an online dashboard.

Between May and November 2023 the sensors measured almost 9.5 million gallons of water through the 1,198 toilets. Flushes accounted for 4.7 million gallons (49 percent). Leaks accounted for 4.8 million gallons (51 percent). The authors note this is a dashboard summary that includes all toilet leaks, not only alerts that staff closed.

Where the toilet water went, May to November 2023 Sensors on 1,198 toilets in eight master-metered properties, about 9.5 million gallons Flushing 49% 4.7 million gallons Leaks 51% 4.8 million gallons 483 leak alerts in seven months; on average 8,284 gallons lost per leak and 10 days before each alert closed
Source: Pacific Institute, Saving Water and Money Through Toilet Leak Detection (April 2024), Figure 3 and Table 3, checked November 2026. Dashboard data reported by the authors, not independently measured.

Over the seven months the system raised 483 leak alerts. On average each leak lost 8,284 gallons before it stopped, and an alert stayed open for 10 days. Two of the eight properties each lost about 1 million gallons to toilet leaks in those seven months.

What the bills showed

Four properties had usable bill data. Comparing May to November 2023 with the same months a year earlier, water use fell 11 percent on average, with a range of 8 to 15 percent. The authors estimate savings of 3,469 gallons per sensor per year and a 12 percent cut in water and wastewater costs, about $81 per sensor per year at Los Angeles rates.

A May 2024 summary from the same group covers 2,900 sensors across 15 affordable multifamily buildings in California and Arizona. It reports preliminary results of a 10 to 15 percent cut in building water use and an estimated benefit of about 5,000 gallons per sensor per year. Both figures are labeled preliminary.

What EPA says about toilets in general

EPA’s February 2026 guide, Know Your Flow and Curb Water Waste, says “about 20 percent of toilets leak.” It also says a stuck fill valve “can waste 4,300 gallons of water per day.” On its residential toilets page, EPA says most toilet leaks are due to old or worn-out flappers.

Treat these numbers as evidence of scale, not as a forecast for your property. The Los Angeles buildings were older affordable housing, mostly for seniors and people with disabilities. The researchers said results varied with the age of the plumbing, resident behavior and how quickly staff responded.

Why one master meter hides toilet leaks

A master meter adds every unit’s water into one number that arrives on a bill weeks after the meter is read. Nobody who hears the running toilet pays the bill, and nobody who pays the bill hears the toilet.

One number for the whole property

The Pacific Institute report explains the problem plainly. A master-metered property “has one meter and receives a single bill for all water used; it is not disaggregated by dwelling unit.” Residents have little financial reason to report a leak that causes no damage. Managers have no easy way to find leaks unless residents tell them.

The bills themselves caused trouble in the pilot. They were read monthly and by hand, and they arrived at least a month after the read. Four of the eight properties had to be dropped from the savings analysis because of bill data problems, one of them a persistent misread that the team attributed to a likely broken meter.

Residents report the leaks they notice

The pilot surveyed residents at three properties. Of 96 who answered, 26 had noticed a toilet leak in their apartment. Of those, 22 reported it, and 18 of the 22 said maintenance came to fix it.

That chain works only for leaks people notice. A flapper that seeps a thin stream into the bowl makes no sound and leaves no puddle. It shows up only on the meter.

In Jackson, a leak is billed twice

JXN Water’s rate page says “water and sewer services are based on water meter readings.” Water that leaks through a toilet goes down the drain, so it is billed once as water and again as sewer, in a single combined rate.

The meter also marks where responsibility changes hands. On its RP3 plumber page, JXN Water says it owns the line from the main to the meter, and “the portion between the water meter and the structure belongs to the property owner.” Every gallon that passes the meter is billed to the account, whether it flushed, leaked or ran out of a broken line under the parking lot.

If you are a resident asking why the bill is high

Some apartment communities pass water charges to residents through a submeter or an allocation formula. A running toilet in your unit can then raise your share. Do the dye test described below and report a leak to maintenance in writing. How charges are split is set by your lease and by state and local rules, which this guide does not cover.

Which toilet parts leak: flappers, fill valves and flush valves

Most apartment toilet leaks start in the tank. Either the flapper no longer seals, or the fill valve keeps running because the water level sits above the overflow tube. Flushometer toilets in clubhouses and leasing offices fail at the valve instead.

How a tank toilet holds water

The Department of Energy’s Federal Energy Management Program (FEMP) describes the parts in Best Management Practice 6. A gravity tank toilet “sends water from the tank into the bowl by releasing a flapper valve between the tank and the bowl.” The fill valve refills the tank after each flush, and a float sets where it stops. The overflow tube carries any excess into the bowl.

The flapper is the weak point. EPA’s Fix a Leak Week page says it is a rubber part that wears out, should be checked periodically and replaced “at least every five years.” A worn flapper “can cause your toilet to flush on its own or silently leak thousands of gallons a year.”

Fill valves and water level

FEMP’s maintenance steps for tank toilets are short. Set the water to the manufacturer’s recommended level so it is “not running over the overflow tube.” Adjust the float if the level is too high. Make sure the fill valve is “not running constantly.”

When the level is set too high, water trickles into the overflow tube and down to the bowl all day. The fill valve keeps topping up the tank to replace it. EPA’s figure for a stuck fill valve, 4,300 gallons a day, shows how large the worst case can be.

Flushometer valves in common areas

Clubhouse restrooms, fitness centers and leasing offices often have flushometer toilets with no tank. FEMP explains that these use diaphragm or piston valves. A dirty or brittle diaphragm gasket, or water pressure too low to seat it, can leave the valve open “resulting in continuous water flow.”

FEMP says to inspect these valves at least once a year. The flush cycle of a 1.6 gallon per flush flushometer toilet “should not exceed 4 to 5 seconds.” When you replace a valve insert, match its flush rating to the fixture.

Symptoms and likely causes

What you notice Likely cause Quick check Usual repair
Color in the bowl after a dye test, no sound Flapper not sealing: worn, warped or not dropping fully Dye test, then watch the flapper drop after a flush Replace the flapper with one that fits the toilet model
Tank refills on its own between uses Flapper seepage lowering the tank level Dye test Replace the flapper
Steady trickle into the overflow tube Water level set too high Lift the lid and compare the level with the mark on the tank Adjust the float to the manufacturer’s level
Fill valve never stops running Fill valve stuck or failed Listen at the tank; adjust the float Replace the fill valve if adjustment does not stop it
Flushometer flush runs long or never stops Clogged bypass hole or worn seal in the valve Time the flush against 4 to 5 seconds Clean or replace the valve insert with the same flush rating

How to find toilet leaks in an apartment building, step by step

Start with the bills and the master meter to size the problem, then dye-test every toilet and record each result. Fix what you find, retest, and repeat on a schedule.

Step 1: Turn twelve months of bills into gallons per day

EPA’s facility leak checklist starts here: “Compile your water and energy bills from at least the last 12 months” and compare readings to spot trends. Convert each bill to gallons with 748 gallons per CCF. Then divide by the days in that billing period, as the Pacific Institute team did, because billing periods vary in length.

Set the result beside occupied units for the same months. A rise in gallons per occupied unit with no change in residents or irrigation is the first sign of leaks.

Step 2: Compare the bills with an expected figure

Estimate what the residents should use. The water use calculator builds a daily figure from flushes, shower minutes, faucet use and laundry. Its default example, a fictional household of four in an older house with 1.6 gallon per flush toilets, comes to 187 gallons a day, or 47 gallons per person.

A gap between the bill and the estimate is a question, not a verdict. Irrigation on the same meter, a pool, a laundry room or a cooling system can explain part of it. The next two steps separate those uses from leaks.

Step 3: Read the master meter in the middle of the night

EPA’s facility checklist says to “read water meters during off-peak hours when water use is lower.” If the meter still shows high use, there may be a leak. FEMP’s Best Management Practice 3, written for large campuses, makes the same point: monitor minimum flow during unoccupied periods, “typically around 3 a.m. or 4 a.m.”

An occupied apartment building never reaches zero flow, so the useful number is the trend. Turn off irrigation timers, read the meter at 3 a.m. and again at 4 a.m., and record the gallons. FEMP says significant increases in minimum flow over time “can be assumed to be leak related.”

Step 4: Check the meter and the reads

In Los Angeles, one property’s results were thrown out because of a persistent read error. Write down your own meter readings on the day the utility reads and compare them with the bill. A mismatch belongs with the utility before any leak hunt.

Step 5: Dye-test every toilet

EPA’s method takes 10 minutes per toilet. “Identify toilet leaks by placing a few drops of food coloring in the toilet tank. If any color shows up in the bowl after 10 minutes, you have a leak.” Flush right after the test so the dye does not stain.

Test every unit toilet and every common area toilet, not a sample. Record the unit, the bathroom, the toilet model, the result and the date. While the dye sits, lift the lid and check the water level against the overflow tube, and listen for the fill valve. Give residents notice of entry as your leases require.

Step 6: Walk the common areas and mechanical rooms

Time each flushometer flush against FEMP’s 4 to 5 seconds. EPA’s facility checklist also lists signs of hidden leaks: pooling water, rust or “signs of moisture or mold on your walls, ceilings, or floors,” and water under water heaters.

Toilets are the focus here, but note other losses as you go. EPA says a faucet dripping once per second “can waste more than 3,000 gallons per year.” An irrigation leak 1/32 of an inch across “can waste about 6,300 gallons of water per month.”

Step 7: Fix, retest and set the next date

Repair each leaking toilet, then repeat the dye test on it. Put the next full sweep on the maintenance calendar before you close out the first. New leaks keep starting (the pilot logged 483 alerts in seven months), so a single sweep describes only one day.

What a toilet leak costs at Jackson’s water and sewer rates

On a JXN Water combined account, a leak costs the rate of the highest block the building reaches each month, because leaked gallons come off the top of the bill. For a building above 350 CCF a month, that is $19.95 per CCF, about $26.67 per 1,000 gallons.

The rate blocks

From March 23, 2026, JXN Water charges these combined water and sewer rates for “all customer classifications” and “all meter sizes.” One CCF is 748 gallons.

Monthly metered use Combined rate per CCF Same rate per 1,000 gallons
0 to 50 CCF (up to about 37,400 gallons) $7.48 $10.00
51 to 150 CCF (up to about 112,200 gallons) $14.96 $20.00
151 to 350 CCF (up to about 261,800 gallons) $17.45 $23.33
351 CCF and above $19.95 $26.67

Each meter also carries a monthly availability charge, from $40 for a 5/8-inch meter to $2,560 for an 8-inch meter. That charge does not change with use, so fixing leaks does not reduce it.

A building averaging more than about 8,600 gallons a day passes 350 CCF in a typical month. Its last gallons, and so any leak, are billed at $26.67 per 1,000 gallons.

The formula

Monthly leak cost equals gallons leaked per day, times 30.4 days, divided by 1,000, times your top-block rate per 1,000 gallons. For a yearly figure, use 365 days. Outside Jackson, use your own utility’s block rate and check whether sewer is billed on water use.

Leak volumeWhere the figure comes fromAt $23.33 per 1,000 gal (151 to 350 CCF)At $26.67 per 1,000 gal (351 CCF and above)
3,469 gallons a yearAverage saving per sensor, Los Angeles pilot$81 a year$93 a year
5,000 gallons a yearPreliminary saving per sensor, May 2024 summary$117 a year$133 a year
8,284 gallons, one eventAverage loss per leak before it stopped, Los Angeles pilot$193 per leak$221 per leak
50 gallons a day (hypothetical slow leak)Illustration only$426 a year$487 a year
4,300 gallons a day for 10 daysEPA's stuck fill valve figure, times the pilot's average 10 days to close an alert$1,003$1,147
4,300 gallons a day for a month (30.4 days)EPA's stuck fill valve figure$3,050 a month$3,486 a month
Calculated from JXN Water's combined water and sewer rates effective March 23, 2026 (jxnwater.com/rates, checked November 2026), the Pacific Institute's April 2024 report and May 2024 summary, and EPA's Know Your Flow guide (February 2026). Rounded to the dollar. Rates change; use your current bill.

Example (fictional). Bayleaf Terrace is a fictional 120-unit garden apartment community in Jackson with one master meter, tank toilets in every unit, a clubhouse and no irrigation meter. Its bills average about 12,600 gallons a day, about 512 CCF a month, so its usage charges come to about $8,594 a month before the availability charge. A planning estimate of about 200 residents at the water use calculator’s 47 gallons per person a day gives 9,400 gallons a day. The gap is 3,200 gallons a day, or about 97,280 gallons (130 CCF) a month. Because the building stays above 350 CCF even without the gap, every one of those gallons is billed at $19.95 per CCF: about $2,595 a month and $31,150 a year. The gap is 25 percent of the volume but about 30 percent of the usage charges, because it all sits in the top block. Suppose the night readings and a full dye sweep show that flappers and two overflowing fill valves explain most of it. The repairs would then be worth roughly that much a year, minus staff time and parts. Every number here is a planning assumption for a fictional property.

The water savings calculator runs the same arithmetic for any steady daily reduction. Enter the gallons a day, your top-block rate and any yearly cost for sensors or service. Its note makes the key point: savings come off the top of the bill.

Toilet leak sensors or scheduled audits: choosing a detection method

Scheduled dye-test audits find leaks that exist on the day of the test. In-line toilet sensors flag leaks the day they start but cost money per toilet and still need staff to act. Every master-metered building needs meter tracking either way.

The options side by side

Method What it catches What it misses Main costs
Resident reporting Noisy running toilets and visible water Silent seeps; leaks residents do not report Signs, a reporting channel, response time
Scheduled dye-test sweeps Flapper seeps present on test day Leaks that start the day after Staff hours, entry notices, parts
Master meter tracking (night reads, a flow monitor on the main line, or utility alerts where offered) A rise in the building’s minimum flow Which unit is leaking Meter access, a monitor, someone to read the trend
In-line toilet sensors Continuous flow through each fill valve, with alerts Leaks upstream of the sensor and leaks onto floors Hardware per toilet, installation, software service
Moisture sensors Water on floors near heaters, washers and sinks Toilet leaks into the bowl, which never touch the floor Hardware per location, batteries

EPA’s Know Your Flow guide describes the two families of devices. Point-of-use devices sit at one fixture, and an in-line toilet device goes “between the toilet water supply and the fill valve,” alerting when water flows continuously. They “may fail to detect leaks if they occur upstream.” Point-of-entry devices on the main line see the whole building, but “the location of the leak is not immediately known.”

Utility metering systems that report frequent reads can flag leaks too, but EPA notes their alerts “can still lag for days.” Leak detection devices cannot earn the WaterSense label. EPA says products certified to ANSI/CAN/IAPMO Z1349 have been tested for features such as alarm response and automatic shut-off.

A property with several buildings on one master meter can add meters of its own. EPA’s facility checklist notes that submeters and temporary flow meters do not need separate utility accounts; they can be used internally “to pinpoint issues.” FEMP suggests meters in different areas or zones, with flow thresholds that flag possible leaks when exceeded.

A building-level reading at 3 a.m. tells staff which building to sweep first. EPA adds that many point-of-entry monitors can alert when water flows continuously for a set time. In an occupied building night flow is rarely zero, so set the threshold above the normal night flow you measured. Adding a meter to a building line is plumbing work for a licensed plumber.

What sensors cost in the pilot

The Pacific Institute report gives one real price, from one vendor, in one city, in 2023. Sensors on the four analyzed properties cost $153,252 for 525 toilets, or $292 per sensor. That covered hardware, installation and seven years of monitoring, all paid up front. Each sensor needed a plumber to install and had a device life of at least 10 years.

At Los Angeles rates, the authors calculated a net present value of $150 per sensor at a 6 percent discount rate and a payback of 3 years and 8 months. Corporate funders and utility rebates paid for the pilot, so the property did not carry that cost.

As an illustration only, re-price the pilot’s average saving at Jackson’s top block. Then 3,469 gallons a year is worth about $92.50, and $292 divided by $92.50 is a simple payback of about 3.2 years. At the preliminary 5,000 gallons, it is about $133 a year and 2.2 years. Neither figure includes repair parts or staff time, and the $292 is a 2023 California price, not a quote.

Decision rules

  • Count first. Record leaks found per 100 toilets in your first full dye sweep, then sweep again 90 days later. If a similar number of new leaks appears, continuous sensing has more to catch. If few return, scheduled sweeps plus meter tracking may be enough.
  • Price at your block. A building in the top block pays $26.67 per 1,000 gallons leaked, while a small building in the first block pays $10.00. The same sensor pays back much faster in the larger building.
  • Match the method to staff time. Sensors replace the hunt, not the repair. If nobody can respond to alerts within a few days, start with scheduled sweeps and fix the response first.
  • Do not skip the meter. Whatever else you choose, keep monthly night readings. They catch the leaks no toilet sensor sees: a broken line, a stuck irrigation valve, a water heater relief valve.

Why detection without a repair routine fails

Sensors and audits only report leaks. Water is saved when someone replaces the part. In the Los Angeles pilot, properties whose staff closed alerts quickly generally lost less water per leak, while the two slowest averaged more than two weeks per alert.

What the alert data showed

The report calls the average days an alert stays open “the metric that most accurately reflects property staff’s engagement.” Only two properties averaged under a week. Two averaged more than two weeks. At one property, staff closed none of the alerts themselves; the system closed them automatically once a leak had stopped for 24 hours.

Slow response, bigger losses (most of the time) Average days an alert stayed open Gallons lost per leak Property F 3 4,927 Property C 4 4,053 Property A 8 2,132 Property B 8 5,931 Property D 9 3,876 Property E 11 19,420 Property G 17 10,596 Property H 18 15,335 Staff at Property H closed none of its alerts themselves; at Property F they closed 91 percent.
Source: Pacific Institute, Saving Water and Money Through Toilet Leak Detection (April 2024), Table 3, May to November 2023, based on closed leak alerts only. Checked November 2026. The authors note the pattern holds "generally" and do not draw statistical relationships.

The pattern is not perfect. Property E closed alerts in 11 days on average but lost the most per leak, over 19,000 gallons, which the authors read as high-intensity leaks at a small building. Still, the three properties with the slowest response include the two highest losses per leak.

The lesson the authors drew

The report’s first lesson is that “direct and consistent engagement with onsite property management staff is essential to maximize long-term water savings.” Before the sensors, staff relied on residents to report leaks, and the change “required a cultural shift.” The project had no formal plan for ongoing staff engagement and no funds for repeat visits after training.

Maureen Erbeznik of the Los Angeles Better Buildings Challenge, interviewed for the report, put the condition simply: property staff “have to commit to using their time and resources to responding to and fixing these leaks.” The authors recommend a structured engagement plan with regular follow-ups and additional training.

The 51 percent figure is the clearest warning. Detection ran for all seven months, yet leaks still took more toilet water than flushing did.

A repair routine that closes the loop

  1. Name one owner for leak findings at each property. Alerts, dye results and resident reports all go to that person.
  2. Open a work order the same day. Record the unit, the bathroom and how the leak was found.
  3. Keep parts on the shelf. Your first sweep records every toilet model. Stock flappers and fill valves for each model so a repair needs one visit, not two.
  4. Set a repair target and track it. Two business days is a reasonable house rule to start with; it is a policy choice, not a standard. Track days open the way the pilot did.
  5. Verify the repair. Repeat the dye test. With sensors, confirm that staff closed the alert after a repair rather than letting it time out.
  6. Log it. Unit, part replaced, date found, date fixed. Units that leak again within months point to a toilet that needs replacing.
  7. Review monthly. Night meter readings, leaks found, average days open and repeat units, on one page for the owner.
1 Find Alert, dye test or night meter read 2 Assign Work order the same day 3 Repair Flapper, fill valve, water level 4 Verify Dye retest; alert closed by staff 5 Log Unit, part, date found, date fixed Monthly review: night meter reads, leaks found, days open, repeat units
Example routine for illustration, built on the Pacific Institute's April 2024 recommendations on staff engagement and EPA and DOE FEMP maintenance guidance. The two-day repair target in the text is a house rule, not a standard.

Flapper replacement and when to replace the toilet instead

Replace a leaking flapper with one that fits the toilet model, set the water level to the manufacturer’s mark and retest. Replace the whole toilet when parts keep failing or the fixture uses more than 1.6 gallons per flush.

Replacing the flapper

EPA’s Fix a Leak Week page gives the practical tip: take the old flapper, or a picture of it, to the store. “Pay attention to the width of the flapper and whether it has a foam float on it that may also need to be replaced.” The owner’s manual or the manufacturer’s website lists the right part.

FEMP’s steps add the check that matters after a dye test shows color. Make sure the flapper “properly drops after a flush.” If it does not drop fully into place and seepage continues, replace it. Then set the water level and confirm that the fill valve shuts off.

In a property with dozens of identical toilets, this becomes a stocking job. Record models during the first sweep, keep the matching flappers and fill valves on hand, and note the replacement date in the log. EPA’s five-year replacement interval gives you a schedule for the whole building.

What not to do

FEMP advises against tank inserts. Displacement dams or bags “may hamper overall toilet operation and increase maintenance costs” because they often need frequent replacement or adjustment. A brick in the tank is the older version of the same idea. Fixing the leak saves water without changing how the toilet flushes.

When the toilet itself should go

EPA says older toilets can use “as much as 6 gallons per flush.” The federal standard is 1.6 gallons, and WaterSense labeled models use 1.28 gallons or less, 20 percent below the standard. EPA estimates that replacing old toilets with WaterSense models saves the average family nearly 13,000 gallons a year.

FEMP recommends assessing a site’s waste lines, water pressure, water quality, use patterns and types of users before choosing replacements. It also points to Maximum Performance testing results for flush performance by model. A toilet that leaks again within months of a new flapper, or has a cracked tank or worn flush valve seat, is a candidate for replacement rather than another repair.

If a property later uses treated greywater or rainwater to flush toilets, FEMP advises monitoring flapper valves and seals for any effect on their useful life. Our article on greywater toilet flushing explains how those systems work in a building.

What to tell residents about running toilets

Residents hear a running toilet long before the owner sees it on a bill. A short, repeated message turns that into a report.

EPA’s workplace advice applies to apartments with little change. Post signs that ask people to report leaks, include who to contact, and spread the word to residents, housekeeping, maintenance and landscaping staff. The May 2024 Pacific Institute summary notes that the sensor installation itself “provides an opportunity to engage and educate residents about leak detection.”

A resident notice can cover four points:

  • What a leak sounds like. A tank that hisses, trickles or refills by itself between uses.
  • How to report it. One phone number or portal, and a promise of when someone will come.
  • What the dye test is. Some residents will try it themselves, and some leaks show only that way.
  • When staff will enter. The date of the dye sweep, with the notice your leases require.

The report’s fourth lesson is that residents “lack opportunities to inform, engage in, and benefit from water projects.” Telling residents what the sweep found, and what it saved the building, is one way to change that.

A 90-day plan for toilet leaks in your building

The plan below fits most master-metered properties and needs no equipment to start. It produces the numbers you need before deciding on sensors.

  1. Days 1 to 7: the bills. Gather twelve months of water and sewer bills. Convert to gallons per day and per occupied unit, and note which rate block the building reaches each month. Our water review checklist lists what to collect.
  2. Days 1 to 14: the meter. Check that your own readings match the bill. Turn off irrigation and record gallons between 3 a.m. and 4 a.m. on two weeknights.
  3. Days 7 to 45: the sweep. Dye-test every toilet in every unit and common area. Record models, results and water levels, and stock parts by model.
  4. Days 7 to 45: the repairs. Open a work order the day each leak is found, fix it, retest it and log it.
  5. Days 45 to 60: the second reading. Repeat the night meter readings. A lower minimum flow is your first measure of what the repairs did.
  6. Days 60 to 90: the decision. Price the gallons with the water savings calculator at your top block. Count new leaks in a second sweep, then choose scheduled sweeps, sensors or both.

Hotels face the same toilet and leak problem at a different scale. Our article on how to reduce water use in a hotel puts fixing leaks near the start of its audit order. More articles for owners of hotels and apartment communities are in the hotels and apartments section.

Maredes is a Jackson, Mississippi company that designs water treatment and reuse systems for one building at a time. A Maredes water review starts with twelve months of bills, the meters and the fixtures, and lists findings in order of cost, with leaks and fixtures first. The apartments page explains how that review fits a multifamily property. If the property later adds a treatment or reuse system, monitoring and service covers the readings, the maintenance log and the reports that keep it working. To talk through your bills, contact Maredes.

Have a building in mind?

If this article describes a question about your home, property or business, tell us about the building. A project starts with a water review and a written summary of what we found.