An ice machine water filter does three jobs: it traps sediment, it reduces chlorine taste and odor with carbon, and, if the cartridge carries a scale-control stage, it slows the mineral scale that hard water leaves on the evaporator. It does not remove the slime and mold that grow on wet parts inside the machine and bin, which the FDA Food Code expects you to clean at the manufacturer’s interval no matter what filter is installed. It does not soften very hard water the way a softener does, and it does not make ice usable during a boil-water notice.
The pages that rank for ice machine filters are mostly written to sell cartridges, and they blur these problems together. This article separates them, shows which certifications on NSF’s listings match which problem, explains how to work out a replacement interval, and covers what to do with the ice, the filter and the machine after a boil-water notice. It is general information, not food safety or health code advice: your health department’s rules govern the kitchen.
What an ice machine water filter can and cannot fix
Four different problems get blamed on “the water” at an ice machine. Each has a different cause and a different fix, and only some of them are a filter’s job.
| Problem you see | Usual cause | What addresses it | Can a cartridge fix it? |
|---|---|---|---|
| Grit, cloudy water, clogged screens | Sediment and particles from the mains or old pipes | A sediment stage, listed for “nominal particulate reduction” under NSF/ANSI 42 | Yes, if the cartridge is sized for the flow |
| Chlorine or “pool” taste and odor in ice and drinks | Disinfectant the utility adds | Carbon listed for chlorine, chloramine, or taste and odor reduction under NSF/ANSI 42 | Yes, for the disinfectant named in the listing |
| White or gray crust on the evaporator and water parts | Hardness minerals, calcium and magnesium | A softener (NSF/ANSI 44 lists “hardness reduction”) or scale-control media, plus descaling on schedule | Partly: a scale-control stage slows scale, but the machine still needs descaling |
| Slime, mold or a musty smell in the ice | Biofilm on wet surfaces inside the machine and bin | Cleaning and sanitizing as the manufacturer directs | No |
| Lead in older buildings | Pipes, solder and fixtures | A cartridge with a lead reduction claim under NSF/ANSI 53 | Yes, if the listing carries the claim |
| A boil-water notice | Possible contamination of the city supply | Turning the machine off and following the notice | No |
The rest of this article takes each row in turn. The short version is that a filter protects the machine and the taste of the ice, while cleaning protects the ice itself.
Ice is food: what the Food Code asks of the machine
The FDA’s Food Code 2022 is, in FDA’s words, “a model” that is “offered for adoption by local, state, and federal governmental jurisdictions.” Mississippi’s food protection rule adopts by reference “the current revision of the Food Code” with state changes (Mississippi Administrative Code, Title 15, Part 13). The exact provisions an inspector enforces are the ones your state or county has adopted, so ask your health department which edition applies.
The 2022 Food Code is plain about ice:
- Ice is food. The definition of “food” includes “ice.”
- It starts as drinking water. Section 3-202.16: “Ice for use as a food or a cooling medium shall be made from drinking water.”
- The machine is cleaned on a schedule. Section 4-602.11(E)(4) covers “ice bins,” “beverage dispensing nozzles” and “enclosed components of equipment such as ice makers.” They are cleaned “at a frequency specified by the manufacturer” or, absent manufacturer specifications, “at a frequency necessary to preclude accumulation of soil or mold.”
- Cleaned surfaces are sanitized. Section 4-702.11 says food-contact surfaces “shall be sanitized before use after cleaning.”
- The water treatment device is serviced and logged. Section 5-205.13 says a device “such as a water treatment device or backflow preventer” shall be scheduled for inspection and service “in accordance with manufacturer’s instructions and as necessary to prevent device failure based on local water conditions,” and that “records demonstrating inspection and service shall be maintained by the person in charge.”
- Drains stay out of the bin. Section 4-204.17: “Liquid waste drain lines may not pass through an ice machine or ice storage bin.” Section 5-402.11 forbids a direct connection between the sewer and a drain from equipment in which food is placed.
- Cooling ice is not served. Section 3-303.11: ice used to cool the outside of food, canned drinks or equipment coils “may not be used as food.”
Section 5-205.13 is easy to overlook. A filter cartridge is a water treatment device, so the Food Code model expects a service schedule and a record, not a cartridge changed when someone remembers.
The Mississippi State Department of Health’s Guidelines for Water Use in Food Facilities, dated February 26, 2016, say the same thing in local terms. “If your ice machines, drink dispensers, etc. have filtration, make sure those filters are maintained and changed in accordance with the manufacturer’s recommendations.” Those without filtration are pointed to NSF’s listing of certified drinking water treatment units.
Scale: hardness, softeners and scale-control media
Scale is the white or gray crust that hard water leaves behind. Penn State Extension’s guide to water softening says hardness depends on “two highly soluble minerals, calcium and magnesium,” which “build up on contact surfaces, possibly plug pipes and damage water heaters,” and that hard water “causes gray or white deposits when water is heated.” In an ice machine the contact surfaces are the evaporator and the parts that carry water over it, and the manufacturer’s cleaning procedure is what removes the deposits.
Reading hardness on a lab report
A laboratory reports hardness in milligrams per liter (mg/L) as calcium carbonate, or in grains per gallon (gpg). Penn State says one grain per gallon “equals approximately 17 mg/l or ppm.” The site’s calculators divide by 17.1, so 150 mg/L is about 8.8 grains per gallon.
| Classification (Penn State Extension) | Grains per gallon | mg/L as calcium carbonate |
|---|---|---|
| Soft | Less than 1.0 | Less than 17 |
| Slightly hard | 1.0 to 3.5 | 17 to 60 |
| Moderately hard | 3.5 to 7.0 | 60 to 120 |
| Hard | 7.0 to 10.5 | 120 to 180 |
| Very hard | Greater than 10.5 | Greater than 180 |
Penn State adds that, in a home, levels below 7.0 gpg “will probably not cause major scaling and soap film.” An ice machine’s maker may set its own water limits, which appear in the installation manual. Read that page before choosing any treatment.
Hardness is not something to guess. Penn State notes that calcium and magnesium have no adverse health effects, and a utility’s annual report may not list hardness at all. JXN Water’s 2025 Water Quality Report, for example, has no hardness figure. A sample from the ice machine’s supply line, analyzed by a certified laboratory, gives the number to work from, along with iron, total dissolved solids and pH.
Softener or scale-control cartridge?
There are two common approaches, and they are not the same product.
A softener exchanges hardness for sodium. Penn State describes the resin trading “its sodium ions” for “the calcium and magnesium ions,” and NSF lists softeners under NSF/ANSI 44, Cation Exchange Water Softeners, with a “hardness reduction” claim. Because ice is eaten and drunk, the sodium matters. Penn State says the exchange “adds 7.5 milligrams per quart for each gpg of hardness removed.” At 8.8 gpg that is about 66 milligrams per quart.
A scale-control stage in a cartridge is different. NSF’s listing search includes polyphosphate and polymaleic acid media as product types. The aesthetic-effects claims under NSF/ANSI 42 are chlorine, chloramine, taste and odor, nominal particulate, zinc and bacteriostatic effects; none of them is a hardness or scale claim. A scale inhibitor in an ice machine cartridge is therefore a manufacturer’s feature, judged by the manufacturer’s data and by what the evaporator looks like at the next cleaning, not by a certified reduction claim.
Neither one removes the need to descale. They change how fast scale returns.
Reverse osmosis: only when the results call for it
Reverse osmosis forces water through a membrane. EPA WaterSense says these systems “can potentially remove water contaminants such as lead, volatile organic compounds (VOCs), PFAS, arsenic, bacteria, and viruses.” NSF lists these units under NSF/ANSI 58, Reverse Osmosis Drinking Water Treatment Systems, claim by claim. It is the right tool when a lab result shows something carbon and softening cannot address, such as high total dissolved solids or a contaminant that only a membrane claim covers.
It has a water cost that grows with an ice machine’s draw. EPA WaterSense says a typical point-of-use unit “will generate five gallons or more of reject water for every gallon of treated water produced,” while a WaterSense labeled unit sends “2.3 gallons of water or less down the drain” per gallon treated. For example, suppose a machine draws 100 gallons a day: at five to one, a typical unit would send about 500 gallons a day to the drain, and a labeled unit about 230. Check the ice machine’s installation manual for any limits on feed water before putting a membrane ahead of it.
Example (fictional). Hollis Mill Diner, an invented 70-seat diner, has an air-cooled batch ice machine that draws up to about 100 gallons a day. Its lab report shows hardness of 150 mg/L as calcium carbonate, about 8.8 grains per gallon, with no measurable iron. To see what a small softener dedicated to the ice line would do, the owner uses the softener sizing calculator with 1 person and 100 gallons per person standing in for the ice line, a softener capacity of 8,000 grains and one day of reserve. The line removes 880 grains a day, so the softener regenerates every 8 days, about 46 times a year, and a once-a-week schedule would need about 7,040 grains of capacity. The same result shows the sodium trade: about 66 milligrams per quart added to the ice water. The owner takes both numbers, and the ice machine’s installation manual, to the decision. These figures are planning assumptions for a fictional business.
Sediment, chlorine and chloramine: what carbon is for
Carbon is the part of an ice machine cartridge that most people notice, because it changes taste. Carbon listed under NSF/ANSI 42, Drinking Water Treatment Units, Aesthetic Effects, reduces chlorine taste and odor, and some carbon carries a separate claim for chloramine. A sediment stage ahead of the carbon catches particles first.
Chlorine and chloramine are separate claims
Water systems disinfect with chlorine or with chloramine, and some, like Jackson’s, use both in different systems. On NSF’s listings, “chlorine reduction” and “chloramine reduction” are separate claims under NSF/ANSI 42. A cartridge certified for chlorine is not certified for chloramine unless its listing says so.
This matters in Jackson. JXN Water’s 2025 report lists chloramine, with a running annual average of 3.0 ppm, in the table for the City of Jackson surface water system (PWSID MS0250008). It lists chlorine, at 1.10 ppm, for the Maddox Road groundwater system (PWSID MS0250012). A restaurant on the surface water system that wants to address disinfectant taste in its ice would look for a listing with the chloramine claim.
Sediment and mechanical filtration
Sediment shows up as grit in the bin, cloudy water in the trough or a strainer that clogs. NSF/ANSI 42 has a “nominal particulate reduction” claim for it. NSF’s listings note that “claims of capacity or rated service cycle are not applicable for mechanical filtration,” so a sediment-only stage is changed by pressure drop or appearance, not by a gallon rating.
Lead and other health claims
Taste claims are not health claims. A cartridge that reduces lead must be listed for “lead reduction” under NSF/ANSI 53, Drinking Water Treatment Units, Health Effects, which also covers claims such as cyst and turbidity reduction. MSDH’s 2016 guidelines say patrons who are children 5 or younger or pregnant women “should use filtered (NSF53 certified filter) water if available,” and bottled water if not. In older buildings a first-draw lead sample at the ice machine’s supply tells you whether this matters. For the full list of what each standard means, see drinking water systems.
Slime and mold: the cleaning a filter cannot replace
No cartridge prevents slime. The FDA’s explanation of section 4-602.11, in Annex 3 of the Food Code, says ice makers and ice bins “must be cleaned on a routine basis to prevent the development of slime, mold, or soil residues that may contribute to an accumulation of microorganisms.” Slime is biofilm. CDC’s Legionella toolkit (version 1.1, 2017) defines biofilm as germs and the slime they secrete that “stick to and grow on any continually moist surface.” The inside of an ice machine is a continually moist surface.
A filter works on the water before it reaches the machine. Biofilm grows on the surfaces inside the machine: the water trough, the distribution tube, the evaporator, the bin walls, the door gasket and the chute. The Food Code therefore ties cleaning to the manufacturer’s schedule and to “accumulation of soil or mold,” not to whether a filter is installed.
Cleaning versus sanitizing
The Food Code treats these as two steps. Cleaning removes scale, slime and soil. Sanitizing, as the Food Code defines “sanitization,” is “the application of cumulative heat or chemicals on cleaned food-contact surfaces” that achieves “a reduction of 5 logs, which is equal to a 99.999%” reduction of representative microorganisms. The definition applies sanitizing to surfaces that are already clean, so the order matters: descale and clean first, then sanitize, then rinse if the procedure calls for it.
Your machine’s manual is where to find the cleaning procedure, the cleaner and sanitizer it calls for, and the parts to remove. Use those products and steps rather than a general kitchen cleaner, and keep the manual where the person doing the work can find it.
Machines that sit idle
An ice machine that sits unused, in a closed dining room, a seasonal bar or a quiet hotel floor, holds standing water in its lines and trough. EPA’s guidance on buildings with low or no use lists “refrigerators/ice makers” among the water-using devices to flush when water has been standing. It adds that such devices “may require additional cleaning steps in addition to flushing (e.g., discarding ice)” and to consult the manufacturer’s maintenance instructions. Before a machine that has been off for weeks goes back into service, discard the ice, flush the supply, replace the cartridge if it has passed its months in service, and clean and sanitize.
Scoops, bins and drains
A few habits keep the bin from undoing a clean machine:
- Scoops. The Food Code’s inspection guidance in Annex 7 says “ice scoops may be stored handles up in an ice bin except for an ice machine.” Keep the scoop in a clean holder outside the bin.
- Nothing else in the bin. Ice used to chill bottles, cans or food on the line is “exterior coolant” under section 3-303.11 and may not go back into drinks.
- The drain. Section 5-402.11 bars a direct connection between the sewer and a drain from equipment that holds food, so the bin and machine drains must not be piped straight into the sewer. After any service work, check that the drain line is not kinked and still discharges as it was installed.
- The door and gasket. These are touched all day and stay damp. Clean them whenever the machine is cleaned, and look at them in between.
Ice machines also appear on CDC’s list of devices that can spread Legionella “through aerosols or aspiration.” For a hotel or care setting, that puts the machine on the building’s water management diagram; our article on Legionella water management programs explains who needs one.
How to read an NSF listing for an ice machine cartridge
A box that says “NSF certified” tells you very little. The listing tells you what the cartridge is certified to do, for how many gallons and at what flow. NSF’s listings are public and searchable by brand, model or standard.
The standards you will see
| Listing category on NSF’s site | What it covers for an ice machine |
|---|---|
| NSF/ANSI 42, Drinking Water Treatment Units, Aesthetic Effects | Chlorine, chloramine, taste and odor, nominal particulate |
| NSF/ANSI 53, Drinking Water Treatment Units, Health Effects | Health claims such as lead, cyst and turbidity reduction |
| NSF/ANSI 44, Cation Exchange Water Softeners | Softeners, with a hardness reduction claim |
| NSF/ANSI 401, Emerging Compounds/Incidental Contaminants | Listed incidental compounds, claim by claim |
| ASSE 1087, Commercial and Food Service Water Treatment Equipment Utilizing Drinking Water | A separate category on the same site for commercial and food service equipment |
What to check on the listing
- The exact model. Match the replacement element number on the listing to the cartridge in your hand. NSF lists some cartridges as components, separate from housings.
- The claims. Each claim is listed by name. A cartridge listed under NSF/ANSI 53 for lead is not certified for every contaminant in that standard.
- The service cycle in gallons. NSF’s commercial listings show a “service cycle” in gallons for each replacement element, except for mechanical filtration.
- The flow rate in gallons per minute. The cartridge should be rated for the flow the ice machine draws during fill, and for any other equipment on the same line.
- The date. NSF states the date the listings are current as of. A model that has dropped off the listing is no longer certified.
When Maredes specifies point-of-use treatment for an ice machine, the specification names the standard and the claim each unit must carry, and the listing is checked before purchase. It does not name a brand.
What a well-built filter line includes
The certified cartridge is only one part of the line. The rest decides whether staff can service it quickly and whether anyone can tell when it is spent.
- One line per machine or per pair of similar machines. An ice machine and a coffee brewer on one cartridge share its gallons, so the ice machine’s interval gets shorter without anyone noticing.
- A shutoff valve before the filter head, so the cartridge can be changed without shutting off the kitchen, and so the line can be closed during a boil-water notice.
- A pressure gauge after the filter. A falling reading is the earliest sign of a loaded cartridge.
- A dated label on the cartridge with the install date and the next due date, matching the log.
- A sample point after treatment, so a laboratory sample can show what the machine actually receives.
- Lead-free fittings. EPA says NSF/ANSI/CAN 372 and 61 certification marks show that plumbing products meet its lead free requirements.
- A licensed plumber to install it, with the drain and air gap as local code requires.
How often to change an ice machine filter
Replace the cartridge at its rated gallons or its maximum months in service, whichever comes first, and sooner if pressure drops or the water changes. Calendar-only schedules such as “every six months” can leave a busy machine running on a spent cartridge for months.
Estimating gallons through the cartridge
You need the daily draw. For an ice machine, that is its potable water use per 100 pounds of ice times the pounds it makes. Two sources give the scale:
- ENERGY STAR’s Version 3.0 criteria cap potable water use for certified air-cooled batch ice makers at 20.0 gallons per 100 pounds of ice for ice-making heads and remote units, and 25.0 for self-contained units. Continuous-type flake and nugget machines are capped at 15.0.
- Your machine’s spec sheet lists its own potable water use per 100 pounds and its harvest rate in pounds per 24 hours.
Multiply the pounds you actually make on a typical day by the gallons per 100 pounds, and divide by 100. If the bin is full by noon on slow days, the machine is not running all day, and the real draw is lower than the rated harvest suggests. A water meter on the ice line answers the question exactly.
Example (fictional). Hollis Mill Diner’s machine makes about 500 pounds of ice on a typical day and uses up to 20 gallons of water per 100 pounds, so it draws about 100 gallons a day through its cartridge. The cartridge’s listing shows a service cycle of 9,000 gallons, and the manufacturer sets a six-month maximum. In the filter life calculator, the gallon rating is reached in 90 days and the time limit in about 182 days, so the cartridge is replaced every 90 days (about 3.0 months), limited by gallons treated, about 4.1 times a year. A calendar-only six-month schedule would have run the cartridge for about three months past its rating. These are planning assumptions for a fictional business.
Signs a cartridge is done before its date
- Pressure on a gauge after the filter falls, or the machine’s fill takes longer than it used to.
- Taste or odor returns in the ice or in drinks.
- The utility issues a notice, or the building has had plumbing work that stirred up sediment.
- The cartridge took in water during a boil-water notice.
The filter life calculator’s “reduction for silt, iron or heavy use” input shortens the interval for supplies that load cartridges quickly. Record every change, with the date, the gallons on the meter if there is one, and the next due date, in a filter maintenance log. That record is what section 5-205.13 of the Food Code model asks the person in charge to keep.
Water use: air-cooled, water-cooled and ENERGY STAR
How an ice machine rejects heat changes its water use far more than any filter does. An air-cooled machine uses a fan; a water-cooled machine runs water through its condenser, and in a single-pass design that water goes straight down the drain.
New York City’s Department of Environmental Protection restaurant guide says water-cooled ice machines with single-pass cooling “use between 100 and 300 gallons of water per 100 pounds of ice produced,” and that an air-cooled machine “can consume less than 50 gallons.” It recommends converting a single-pass machine to closed-loop recirculation or replacing it with an air-cooled model. It also notes that the NYC Plumbing Code prohibits new water-cooled machines producing more than 500 pounds a day; that is New York City’s rule, shown here as an example, and local codes elsewhere differ.
ENERGY STAR says certified batch-type ice makers “are about 10 percent more energy efficient and 20 percent more water efficient when compared with standard models,” and save businesses “700 kWh and $150 annually.” Water-cooled ice makers are not eligible for the label.
For a filter, the point is simple: a machine that uses less water per pound of ice puts fewer gallons through the cartridge, so the same cartridge lasts longer. For how ice machines compare with dishwashing, pre-rinse valves and restrooms in a restaurant’s total water bill, see our article on restaurant water use.
Ice machines during and after a boil-water notice
During a boil-water notice, the health department guidance cited here shares a core: turn the ice machine off, throw out ice that may have been made with tap water, and use packaged ice from an approved source if you are allowed to operate. A filter does not change this. CDC’s drinking water advisory guidance says that during any type of advisory, “do not drink or use water from appliances connected to your water line,” and to “boil your tap water even if you filter it.”
State health departments spell out the details, and they do not all say the same thing. Two published examples:
| Topic | New York State Department of Health | Washington State Department of Health |
|---|---|---|
| Staying open | "The safest thing to do is to close," but an establishment may stay open if customers and staff can be protected, unless the health department directs otherwise | Food establishments "must close unless the local health agency authorizes them to stay open" |
| Ice already made | Usable only if certain it was made well before the notice; otherwise discard | Discard ice made with contaminated water; use packaged ice from an approved source |
| Ice machine | Empty, unplug and label "Do Not Use"; do not restart until the notice is lifted and the lines and machine are flushed and disinfected | Shut off |
| Ice bin and scoops | Bin, scoops and ice buckets washed and disinfected before use | Not addressed separately |
| After the notice | Flush lines at least 5 minutes; flush and disinfect ice machines per the manufacturer; backwash or replace water filters | Contact the local health agency for approval to resume and set a protocol for turning equipment back on |
Restarting the machine after the notice lifts
Put the steps in this order, and confirm them against your health department’s instructions and the machine’s manual:
- Confirm the notice is lifted for your address with the utility or the health department. In Jackson, check JXN Water’s notice page and MSDH’s water safety notices.
- Flush the cold water lines in the building, starting nearest the meter. New York’s guidance says at least 5 minutes, longer for long or complex service connections.
- Replace the cartridge that took in water during the notice, or backwash it if the manufacturer allows. Flush the new cartridge as its instructions direct.
- Discard any remaining ice, then clean and sanitize the machine, bin, scoops and buckets using the manufacturer’s procedure.
- Run the first batches to waste if the manual calls for it, then return the machine to service.
- Record it: the date, the notice, the cartridge change and who did the work, in the same log as routine changes.
The boil-water notice checklist covers the rest of the building. For whether a restaurant may stay open at all, and what else changes in the kitchen, see our article on restaurants during a boil-water notice.
A service routine for one ice machine
A routine that fits on one page is more likely to be followed than a binder. The intervals below that come from a rule or a manual say so; the rest are practical habits.
| When | Task | Basis |
|---|---|---|
| Every shift | Scoop stored outside the bin in a clean holder; bin door kept closed; nothing chilled in the ice bin | Food Code 3-304.12 and Annex 7; 3-303.11 |
| Weekly | Look inside the bin and at the door gasket and chute for slime or mold; check the drain air gap | Practical habit; Food Code 4-602.11 sets the standard of no accumulation of soil or mold |
| Monthly | Read the pressure gauge after the filter; note the water meter reading if there is one | Practical habit; supports 5-205.13 records |
| At the cartridge interval | Replace the cartridge at rated gallons or months, whichever comes first; log it | Manufacturer’s rating; Food Code 5-205.13; MSDH 2016 guidelines |
| At the manufacturer’s cleaning interval | Descale, clean and sanitize the machine and bin with the specified products | Food Code 4-602.11(E)(4) and 4-702.11 |
| After any notice or plumbing work | Flush lines, replace the cartridge, clean and sanitize, log | Health department instructions; NY DOH example |
| Once a year | Review the log; retest the water if taste, scale or equipment life has changed | Practical habit |
The weekly look is the early warning. Slime in the chute or a pink film on the gasket means the cleaning interval is too long for this machine in this kitchen, whatever the manual’s minimum says, which is exactly the case the Food Code’s “absent manufacturer specifications” language anticipates.
Mistakes that cost a cartridge or a cleaning
- Buying by the word “certified.” The claim on the listing is what matters: chlorine is not chloramine, and taste is not lead.
- Skipping the start-up flush that a new cartridge’s instructions call for before the machine refills.
- Sharing one cartridge among several machines without adding their daily draws together.
- Replacing a filter to fix slime. Slime lives on the machine’s surfaces, so it needs cleaning and sanitizing.
- Cleaning without sanitizing, or sanitizing a surface that still has scale on it.
- Restarting after a notice on the old cartridge. Any cartridge that took in water during a boil-water notice is replaced.
- Leaving no record. Without dates and readings, nobody can tell whether the interval is right.
What to do next
Start with what is actually wrong. If the complaint is taste, the fix is carbon with the right claim. If it is scale, you need a hardness number before choosing between a softener and a scale-control stage. If it is slime, the fix is cleaning, and a new filter will not help.
- Get the water tested at the ice machine’s supply line by a certified laboratory: hardness, iron, total dissolved solids, pH, and a first-draw lead sample in older buildings.
- Find out which disinfectant your utility uses from its Consumer Confidence Report, and match the carbon claim to it.
- Look up your cartridge on NSF’s listing and write down its claims, service cycle in gallons and flow rate.
- Work out the replacement interval with the filter life calculator, using your machine’s real daily draw.
- Put the cleaning interval from the manual on the calendar, and shorten it if the weekly look finds slime.
- Write a one-page boil-water plan for the ice machine and other water-connected equipment.
- Keep one log for cartridges, cleaning and notices.
Maredes is a Jackson, Mississippi company that designs water treatment and reuse systems for one building at a time, starting with a laboratory test of the water. For a restaurant, that means treatment for each ice and beverage line specified by the certification its lab results call for; see restaurants and food service. If you would like help reading a lab report or planning an ice line, you can get in touch. More articles on kitchens, equipment and building water are under commercial water.