Every hotel sustainability certification starts its water section in the same place: a meter-based record of total water use, usually month by month, and evidence that the hotel is working to lower it. Past that, the programs differ. Green Key’s 2026 to 2031 criteria set fixture flow limits and a written leak-check routine, Green Key Global’s Eco-Rating requires a hotel to track annual water use and report its share of low-flow fixtures, Green Seal’s GS-33 caps fixture flows and requires linen reuse, and LEED v5 for existing buildings scores a full year of metered water per square foot. Efficiency measures count in all of them; reuse counts most directly in Green Key’s guideline criteria and in LEED, where it lowers the metered total of drinking water.
This article reads each program’s own published documents, as loaded in November 2026, and nothing else. Program names and versions matter: two different organizations use the Green Key name, Green Seal has paused new applications, and LEED v5 is now USGBC’s latest version. Maredes is not affiliated with, endorsed by or certified by any program described here.
What every hotel certification asks about water
All four programs come back to the same three things: a record of how much water the hotel uses, the fixtures and equipment that use it, and a plan or routine that keeps use falling. LEED v5 for existing buildings judges fixtures only through the metered total; the others name them directly.
The table below sets the water requirements side by side. Each cell summarizes the program’s own document; the chapters that follow give the detail and the criterion numbers.
| Topic | Green Key 2026 to 2031 (FEE) | Green Key Global Eco-Rating, core criteria | Green Seal GS-33, Edition 5.3 | LEED v5 O+M, existing buildings |
|---|---|---|---|---|
| Open to U.S. hotels | No: FEE says the programme does not operate in the U.S. or Canada | Website offers Canada and U.S. regions | Standard under review; new applications not accepted | Yes; LEED v5 is USGBC's latest version |
| Water records | Total use recorded at least monthly (imperative); 2 calendar years of monthly data at audit | Annual water use and costs measured and tracked, documents uploaded | Gold option: monthly bills in Portfolio Manager or equivalent, reviewed yearly | Meters for potable and alternative water; 12-month reporting period (prerequisite) |
| Fixtures | 80% of showers at most 9 L/min, 80% of hand taps at most 8 L/min; limits on new toilets (imperative) | Must report share of rooms with low-flow showerheads, aerators and low-flow toilets | WaterSense labeled, or at most 2.2 gpm faucets, 2.5 gpm showerheads, 1.6 gpf toilets | No fixture list; points come from metered use |
| Leaks | Written check-and-repair procedure with an incident log (imperative) | Preventive maintenance covers plumbing; housekeepers report faults | Leak checks named as an example of HVAC and appliance maintenance (2.2.3) | Not a separate requirement; weekly meter reads for the submeter credit |
| Laundry and linens | Housekeeping applies towel and sheet reuse; new laundry machines at most 7 L per kg | Guests can opt out of housekeeping (mandatory) | Linen reuse for multi-night guests; machines filled to capacity | Counts through metered use; a laundry subsystem meter can earn the submeter point |
| Reuse | Rain or AC condensate use and treated wastewater reuse (guideline) | Not in the core questions | Rain or gray water named as alternatives for cleaning hard surfaces | Lowers potable total; alternative water metered separately |
| How it is checked | On-site audit with room sampling; certificate valid 2 years | Assessment with uploaded documents, then an audit | On-site auditor visit | Data reported for review on the Arc platform |
The common core
Three habits satisfy part of every program at once. Read and record the water meter every month. Inventory every showerhead, faucet and toilet with its rated flow. Write down how staff find and fix leaks. A hotel that already does these three things has most of the water evidence any program asks for in its first year.
Which programs a U.S. hotel can apply to in late 2026
LEED v5 and Green Key Global’s Eco-Rating are the two programs in this comparison whose own pages show them serving U.S. hotels. FEE’s Green Key does not operate in the United States, Green Seal has paused new hotel applications, and EPA’s H2Otel Challenge has ended.
Two programs share the Green Key name
The Foundation for Environmental Education (FEE) owns the international Green Key programme, with criteria published at greenkey.global. Its join page states: “The Green Key programme operated by FEE does not operate in the United States or Canada.” FEE says it works through national operators in 50 or more countries.
Green Key Global runs a separate Eco-Rating with its own core criteria, and its website offers regions for Canada and the United States. EPA’s green hotels resource page, last updated September 14, 2026, lists a “Hotel Association of Canada - Green Key Eco-Rating Program” among eight green hotel programs. If someone offers your U.S. property a “Green Key” rating, confirm which organization runs it and read that organization’s criteria.
FEE’s criteria still matter to U.S. readers. Brands with hotels abroad meet them, and they are the most detailed public water criteria in this group. They are described in full below.
Green Seal’s hotel standard is under review
Green Seal’s GS-33 page says: “This standard is currently under review. New certification applications are not being accepted at this time.” The latest version is Edition 5.3, issued June 6, 2017, and republished with corrections on January 31, 2025. Its water rules are still worth reading as a reference.
LEED v5 is the current LEED version
USGBC’s LEED v5 page calls LEED v5 “the latest version” of LEED, with rating systems for new construction, interiors and operations and maintenance. An operating hotel would normally look at Operations and Maintenance (O+M). A new hotel or a major renovation would look at Building Design and Construction (BD+C).
EPA’s H2Otel Challenge has ended
EPA launched the WaterSense H2Otel Challenge in 2014 and says more than 860 hotels signed up. The page now says “the formal Challenge is no longer active.” Its tools remain: the WaterUSE Tool, Water Assessment Worksheets and the Saving Water in Hotels fact sheet. Older program guides, including Green Seal’s 2024 guidebook, still suggest joining the Challenge.
Other programs on EPA’s list
EPA’s list also names Green Globe, Audubon International’s Green Hospitality Program, the Green Hotels Association, the American Hotel and Lodging Association’s resources, the World Travel and Tourism Council and the Global Sustainable Tourism Council. EPA notes that Green Globe members “can view the Green Globe Standard with a complete set of criteria online.” This article covers only programs whose water criteria could be read in full in a public document.
Hotel Sustainability Basics
Green Key also published a document checklist for verifying Hotel Sustainability Basics, a shorter scheme; the file’s address dates it to 2023. Under “E2. Measure and reduce water,” a hotel submits total water consumption, consumption per occupied room and monthly or quarterly totals in cubic meters, with the bills, plus a water reduction plan with at least three actions. A Hotel Water Measurement Initiative result is optional. Water is one of four efficiency criteria, of which a hotel must meet two, and bed linen reuse sits in a separate category.
Green Key’s current criteria pages do not mention the scheme, and FEE’s Green Key does not operate in the U.S. A U.S. hotel interested in it should first confirm who verifies it and whether it is still offered.
Green Key 2026 to 2031: the most detailed water criteria
FEE’s Green Key has 17 water criteria for hotels and hostels: 9 imperative ones every certified hotel must meet and 8 guideline ones that count toward a rising percentage. They cover monthly metering, leak routines, fixture flow, new appliances, wastewater, metering by area, risk assessment and reuse.
How the criteria are applied
The Hotels and Hostels criteria are valid from October 1, 2026 to December 31, 2031. They apply to hotels with more than 20 bedrooms or 40 beds. A hotel must meet 100 percent of imperative criteria. The required share of guideline criteria rises from 0 percent in years 1 and 2 to 10, 20, 30, 40 and finally 50 percent from year 11.
A certificate is valid for two years. FEE says an on-site audit usually takes 2 to 6 hours, and surveillance follows 8 to 14 months after certification.
Imperative water criteria
- 3.1 Monthly water records. Total water use is recorded at least once a month, with the source and method stated (bills, submeters, manual readings). The auditor sees monthly records for the last two calendar years; first-time applicants show the last full year, or at least three months. The glossary defines a “major change” to investigate as more than 20 percent above the baseline in consumption intensity, for example per bed night.
- 3.2 Leaks. A written Standard Operating Procedure sets checks by outlet type. High-use outlets, including guest rooms and public restrooms, are checked “at least each time the area is cleaned”; staff bathrooms and back-of-house kitchens weekly; seldom-used outlets monthly or before use. Leaks and repairs go in an incident log.
- 3.3 Showers. At least 80 percent of showers flow at no more than 9 liters per minute, with documented self-checks of flow.
- 3.4 Hand taps. At least 80 percent of handwashing taps flow at no more than 8 liters per minute.
- 3.5 Urinals. Sensors, push buttons flushing no more than 3 liters, or waterless.
- 3.6 New toilets. Toilets bought recently are dual flush at no more than 3 and 6 liters, or sensor-flushed at no more than 4.5 liters.
- 3.7 New dishwashers and laundry machines. Professional dishwashers use no more than 3.5 liters per basket; professional laundry machines no more than 7 liters per kilogram of linen, or the strictest threshold available locally where such models are not reasonably available.
- 3.15 Wastewater. All wastewater is treated, with proof of connection for hotels on a public sewer.
- 3.16 Grease traps in professional kitchens, with cleaning records.
Housekeeping criterion 1.22 is also imperative: staff know and apply the hotel’s towel and sheet reuse procedures.
Guideline water criteria
- 3.8 At least two additional separate water meters in high-use areas.
- 3.9 A water risk assessment within the past six years. In urban areas served by a utility, official utility data “may serve as the basis for the assessment.”
- 3.10 Rainwater or air-conditioning condensate collected and used, for example for irrigation, toilet flushing, cleaning or cooling systems, with a meter recommended.
- 3.11 All handwashing taps at no more than 5 liters per minute.
- 3.12 Automatic shut-off on public handwashing taps.
- 3.13 No bathtubs, spa tubs or private pools in guest rooms.
- 3.14 Evaporation control on pools, hot tubs, fountains and storage.
- 3.17 Treated wastewater reused for non-potable purposes only, “never used for human consumption or direct contact.”
What the auditor checks on site
For leaks, showers and taps, the auditor samples at least one public area, one staff or back-office area and a set of guest rooms. Green Key’s glossary sets the room sample by size: 3 rooms for hotels with 6 to 50 rooms, 4 rooms for 51 to 150, and at least 5 above 150. In sampled rooms the auditor operates fixtures, “running water” among the listed tests.
Flow self-checks must be documented within the six months before the audit. First-time applicants self-check at least 80 percent of showers and handwashing taps; re-applicants recheck at least half of the fixtures in their previous 80 percent group.
Hotels certified under the 2022 to 2026 criteria keep using them until they re-apply. During the transition, which ends no later than December 31, 2027, re-applicants may provide six months of data where two calendar years would normally be required.
Example (fictional). The fictional Pearlbank Hotel has 96 rooms, so a Green Key auditor would sample 4 guest rooms. Its bills show about 300,000 gallons a month, about 401 CCF or roughly 1,136 cubic meters, and about 147 gallons per occupied room-night, roughly 0.56 cubic meters. Those monthly figures, with the bills behind them, are the core of criterion 3.1. The two running toilets its water review found, fixed by hotel staff before any design, would be two entries in the 3.2 incident log, each with the date found and the date fixed. If a later month ran above about 176 gallons per occupied room-night, 20 percent over that baseline, it would count as a “major change” to investigate. Every number here is a planning assumption for a fictional hotel.
What the metric limits mean in gallons
The liter figures are the limits. The criteria text converts 9 liters to “2.68 US gallons” and 8 liters to “2.81 US gallons,” but 9 liters is about 2.38 gallons and 8 liters about 2.11. The 5-liter guideline is about 1.32 gallons per minute.
That gap matters in a U.S. hotel. EPA’s showerhead page says standard showerheads use 2.5 gallons per minute (about 9.5 liters), so they exceed Green Key’s 9 liters. WaterSense labeled showerheads use no more than 2.0 gallons (about 7.6 liters) and pass. On faucets, EPA’s bathroom faucet page gives a standard flow of 2.2 gallons per minute (about 8.3 liters), just over the 8-liter limit, while WaterSense labeled faucets at 1.5 gallons (about 5.7 liters) pass the imperative limit but not the 5-liter guideline.
Toilets need a closer look. WaterSense single-flush toilets use 1.28 gallons, about 4.8 liters. Green Key’s 3.6 accepts other efficient models “provided that technical specifications demonstrate that average water use per flush cycle” is within its 3/6-liter or 4.5-liter figures. Check a model’s specification against that wording, with the program, before buying a lot of toilets.
Green Key Global’s Eco-Rating: what the core questions ask on water
Green Key Global’s core criteria are yes-or-no and select-all questions, several with answers marked mandatory. On water, a hotel must track annual water use and costs, run linen reuse and preventive plumbing maintenance, and report how many rooms have low-flow fixtures.
How the Eco-Rating is built
Its core criteria page describes 37 questions in the current Eco-Rating assessment as the minimum for a 1-Key rating, and says “all Core Criteria questions must be completed to be eligible to submit your assessment and qualify for an audit.” Members may answer additional questions to pursue a higher rating. The core questions document calls them “the mandatory baseline within the Eco-Rating self-assessment.”
The water-related core questions
| Question | What it asks | Required answer |
|---|---|---|
| Corporate Q1d | Sustainability policy commitments | Must include “Water conservation” |
| Corporate Q2b | Contents of the management action plan | Must include “Ongoing measurement and monitoring” |
| Housekeeping Q1 | A formal program letting guests opt out of housekeeping (reuse linens or towels) | Yes |
| Housekeeping Q20 | Housekeeping staff trained to minimize water use when cleaning | Yes |
| Housekeeping Q21 | Housekeepers trained to report faulty equipment to maintenance | Yes |
| Engineering Q11 | Annual use and costs of water measured and tracked | Yes, with documents uploaded |
| Engineering Q15 | Preventive maintenance program | Must include plumbing |
| Engineering Q40 | Share of guest rooms with low-flow showerheads (1.5 to 2 gpm) | Select the share; no minimum stated |
| Engineering Q41 | Share of guest rooms with tap aerators (0.5 gpm) | Select the share; no minimum stated |
| Engineering Q42 | Share of guest rooms with low-flow toilets (1.1 to 1.6 gpf), dual-flush toilets, toilet dams or tank fill diverters | Select the share; no minimum stated |
The core set leans on management and training rather than hard limits. The core document sets no minimum share for low-flow fixtures; the hotel reports what it has.
One practical note on Q42. The U.S. Department of Energy’s Federal Energy Management Program advises against tank displacement devices, saying they “may hamper overall toilet operation and increase maintenance costs.” If you are choosing between a dam and a replacement toilet to raise your Q42 share, weigh that guidance.
Green Seal GS-33: fixtures, grounds, linens and Gold-level metering
GS-33 has three levels, Bronze, Silver and Gold. Its water section sets fixture limits, landscaping and linen rules for every level, and adds metering and WaterSense-only fixtures as options at Gold.
Section 2.3, management of fresh water resources
- 2.3.1 Water-efficient fixtures (all levels). “All fixtures shall be WaterSense labeled or have flow rates that do not exceed” 2.2 gallons per minute for faucets and aerators, 2.5 for showerheads and 1.6 gallons per flush for toilets. Faucets and showerheads over these limits go on a replacement schedule completed within two years of first certification. Toilets over the limit are replaced at the next major room renovation. Exemptions need a demonstration that high flow is required, or a plumbing contractor’s attestation for toilets.
- 2.3.2 Landscaping and irrigation (all levels). New outdoor plants are native or tolerant of local conditions, irrigated grass only where guests use it, and irrigation that uses soaker hoses or drip for beds, mulch, and watering early in the morning or at night.
- 2.3.3 Groundskeeping (Silver and Gold). Sidewalks, drives and parking lots are not washed down with potable water. The 2024 guidebook names sweeping, rainwater or gray water and machines that recycle wash water as alternatives.
- 2.3.4 Towel and linen reuse (all levels). Guests staying two or more nights can choose to reuse towels and linen, unless the property shows this is not cost-effective.
- 2.3.5 Washing capacity (all levels). Washers, dryers and dishwashers are filled to the recommended capacity and use the coolest effective water temperature.
Gold level: track the bills, meet WaterSense everywhere
At Gold, a property meets three of eight additional requirements. Two concern water. Under 2.7.2, it tracks potable water use with “monthly bills” in ENERGY STAR Portfolio Manager “or an equivalent resource management or documentation system.” The system tracks cost, total use and resource use intensity, benchmarks against past performance normalized for sales volume, and is reviewed at least annually.
Under 2.7.8, the property “shall meter and monitor its water consumption,” and “all of the toilets, bathroom faucets, shower heads, and landscape irrigation shall meet the EPA WaterSense requirements.” The 2024 guidebook asks for at least three months of tracking at application and twelve months for compliance monitoring.
LEED v5 for existing hotels: a year of metered water per square foot
LEED v5 O+M scores water on performance, not on a fixture list. A hotel must meter all its water and report 12 months of use. It earns 1 to 14 points by beating a water use intensity threshold, and 1 more point for metering two water subsystems.
The three water items
USGBC’s LEED v5 O+M Reference Guide (July 2026 edition) gives the Water Efficiency category 15 of 110 possible points.
- WEp1 Water Metering and Reporting (required). Permanent meters record total consumption from potable and alternative sources for the building and grounds. Alternative sources are metered “separately from municipally supplied potable water.” The project reports a full 12-month period and commits to share whole-project water data with USGBC each year after certification.
- WEc1 Water Efficiency Performance (1 to 14 points). Points come from potable water per square foot per year. For hospitality, the 1-point threshold is 49 gallons per square foot per year (1,997 liters per square meter). Each further reduction step adds a point, up to 14 points at 50 percent below the threshold.
- WEc2 Advanced Water Metering (1 point). Permanent meters on at least two subsystems: irrigation, indoor fixtures, cooling towers, domestic hot water, reclaimed water or other process water such as dishwashers, clothes washers and pools. All meters, including the whole-building meter, are recorded “at least weekly.”
Example (fictional). The Pearlbank Hotel, the fictional 96-room select-service hotel used across this site, uses about 300,000 gallons a month, or 10,000 gallons on an average day: about 3.65 million gallons a year. The example does not state its gross floor area, so LEED v5’s metric cannot be computed directly. What it can show is the floor area at which Pearlbank would sit exactly at the hospitality threshold: 3,650,000 divided by 49, about 74,500 square feet. Pearlbank’s planned reuse systems would replace 1,300 gallons a day of city water, 13 percent of supply. For any hotel that starts exactly at the threshold, a 13 percent cut in metered potable water passes the 10 percent step and is worth 4 points instead of 1; a 14 percent cut would reach 5. Under WEp1, the reuse water would need its own meter. Every number here is a planning assumption for a fictional hotel.
If your hotel is on LEED v4.1
LEED v4.1 for existing buildings uses a different water method. USGBC’s Guide to Water Metering (January 2020) describes the v4.1 O+M prerequisite: permanent meters for total potable water, “12 consecutive months” of reported use, and a calculated Water Performance score. USGBC’s v4.1 O+M scorecard lists that Water Performance prerequisite as worth up to 15 points.
LEED v5 for new and renovated hotels
For a new hotel or a major renovation, LEED v5 BD+C adds a fixture prerequisite and rewards submeters, leak sensors and reuse. These are design decisions, best made before the plumbing drawings are final.
Minimum Water Efficiency (WEp2, required)
USGBC’s LEED v5 BD+C Reference Guide (July 2026 edition) offers two paths. The prescriptive path caps every fixture: 1.28 gallons per flush for toilets, 0.50 for urinals, 0.50 gallons per minute for public lavatory faucets, 1.50 for private lavatory faucets, 1.8 for kitchen faucets and 2.00 for showerheads. For dual-flush toilets the full flush must be 1.28 gallons or less, and “a weighted average cannot be used.” The performance path instead cuts aggregate fixture use 20 percent below a baseline.
The prerequisite also sets equipment rules for new appliances (ENERGY STAR or equivalent for commercial clothes washers up to 8.0 cubic feet, ice machines and others, and gallons-per-rack limits for dishwashers). It requires either no permanent irrigation after establishment or a 30 percent cut in the site’s theoretical irrigation requirement.
Water Metering and Leak Detection (WEc1, 1 point)
There are two options. Submeters cover indoor fixtures, irrigation, each makeup water system, the commercial kitchen if it serves at least 100 meals a day, and the laundry if it processes at least 120,000 pounds a year. All must record at least hourly, with real-time access.
Or install leak detection sensors on irrigation, at least 50 percent of flush fixtures and each makeup water system. The system must alarm on abnormal flow or detected water, and the team writes an action plan covering how the manager “will address and remedy any detected leak.”
Enhanced Water Efficiency (WEc2, up to 8 points)
Points come either from a whole-project water use model (30 to 65 percent below baseline) or from a combination of options. On-premise laundries processing at least 120,000 pounds a year can earn a point with washers at no more than 1.8 gallons per pound. Water reuse earns 1 point for a reuse-ready supply system, or 2 points for an on-site reuse system or municipal reclaimed water serving irrigation, flush fixtures, makeup water or other process uses.
What a hotel water management plan needs for any of these programs
A water management plan for certification is a written record of where the hotel’s water goes, what it costs, which measures come next and who tracks the results. It is a different document from a Legionella water management program, which manages the risk of bacteria growing in building water systems.
The conservation plan
The programs ask for it in different words. Green Key requires strategic targets, with “reducing total water consumption per guest night by 10%” given as an example, and an annual action plan. Green Key Global’s core criteria require a management action plan with “ongoing measurement and monitoring.” Green Seal’s standard includes a continual improvement plan with quantifiable metrics (not required at Bronze), and at Gold an annual review of tracked water use.
None of them gives a template. DOE’s Best Management Practice 1, Water Management Planning, written for federal facilities, sets out seven steps that fit a hotel:
- Set a policy and goals, with management support in writing.
- Assess current water uses and costs, including the marginal water and sewer rate and two years of bills.
- Build a water balance: compare total supply with estimated end uses. FEMP says losses above 10 percent of supply probably warrant investigation, which can include leak detection.
- Assess efficiency opportunities and their life-cycle economics.
- Write an implementation plan with owners and dates.
- Measure progress, with submeters on water-intensive processes.
- Plan for contingencies such as emergencies and droughts.
A plan built this way also gives a hotel the inputs that Green Key’s 3.1 and 3.8, Green Seal’s 2.7.2 and LEED’s WEp1 ask to see.
Pick the denominators before the first report
Each program divides water use by something different, and switching later breaks the trend line. Green Key’s examples use per bed night and per guest night. The Hotel Sustainability Basics checklist uses per occupied room. Green Seal’s Gold tracking uses a resource use intensity such as gallons per square foot, benchmarked “normalized for sales volume.” LEED v5 uses gallons per square foot per year.
Keep three series from the start: total gallons, gallons per occupied room-night and gallons per square foot per year. Record guest counts too if your property management system holds them. Each later report then draws on data you already have.
The Legionella program is separate
CDC’s water management program worksheet, dated March 15, 2024, says “an effective water management program is the primary strategy to control Legionella growth and spread.” Its device questions include a cooling tower, “a hot tub (also known as a spa) that is not drained between each use,” and a decorative fountain. Many hotels have at least one. Reuse systems add tanks and stored water, so a hotel adding reuse for certification should also review its Legionella program. Our Legionella checklist is a starting point.
Which water measures count toward which program
Monthly metering and efficient fixtures count everywhere. Reuse, submeters and leak routines count in some programs and not others, so the order of work depends on which program you are preparing for.
| Measure | Green Key 2026 to 2031 | Green Key Global core | Green Seal GS-33 | LEED v5 O+M |
|---|---|---|---|---|
| Monthly meter readings | Imperative (3.1) | Annual tracking required (Q11) | Gold option (2.7.2) | Required (WEp1) |
| Submeters on laundry, irrigation, cooling | Guideline (3.8) | Not in core | Gold option to meter and monitor (2.7.8) | 1 point (WEc2) |
| Written leak routine and log | Imperative (3.2) | Plumbing in maintenance program (Q15) | Leak checks as an example of equipment maintenance (2.2.3) | Counts only through lower use |
| WaterSense showerheads and faucets | Meets 3.3 and 3.4 | Raises reported shares (Q40, Q41) | Meets 2.3.1; all required at Gold option 2.7.8 | Counts only through lower use |
| Towel and linen reuse | Imperative for housekeeping (1.22) | Mandatory (Housekeeping Q1) | Required (2.3.4) | Counts only through lower use |
| Efficient laundry machines | New machines 7 L per kg or less (3.7) | Not in core | Full loads, coolest effective temperature (2.3.5) | Counts only through lower use |
| Rain or AC condensate for irrigation or flushing | Guideline (3.10) | Not in core | Named alternative for hard surfaces (2.3.3) | Lowers potable total; meter it separately |
| Greywater or treated wastewater reuse | Guideline, non-potable only (3.17) | Not in core | Named alternative for hard surfaces (2.3.3) | Lowers potable total; meter it separately |
Efficiency first, then reuse
Every program rewards lower metered use, so the cheapest gallons come first: leaks, fixtures, then laundry and landscape practices. Our article on how to reduce water use in a hotel orders those measures as an audit sequence. Reuse then works on what is left, and in LEED its effect shows up only if it is metered.
For laundry, the choice between equipment upgrades and water recycling is covered in ozone laundry or laundry water recycling. For greywater, greywater recycling in hotels looks at what installed systems required of their owners.
Reuse is non-potable in every program that names it
Green Key’s 3.17 limits treated wastewater to non-potable uses such as irrigation, toilet flushing and cooling. Mississippi is not among the 12 states that EPA’s onsite reuse page lists as having onsite non-potable reuse regulations or guidelines, so approval is project by project with the local building official and, where wastewater is involved, the health department. The standards page lists the NSF/ANSI 350 classes, backflow protection and purple pipe labeling that Maredes writes into reuse specifications, and it states that Maredes itself holds no certifications.
What a saved gallon is worth in Jackson
Certification points and lower bills come from the same gallons. On a JXN Water combined account, water and sewer are billed from the water meter, and from March 23, 2026 the top block costs $19.95 per CCF (748 gallons), about $26.67 per 1,000 gallons, according to JXN Water’s rate page. Price any measure at the block your hotel actually reaches each month.
Preparing the water evidence: a 90-day checklist
The work below produces the records every program in this comparison asks for, before you choose a program or pay an application fee.
- Confirm the program and version. Write down the organization, the criteria version and whether it accepts U.S. applications. Two Green Keys and two LEED versions make this the most common mistake.
- Pull 24 months of water bills. Green Key asks for two calendar years; FEMP suggests two years of bills. Convert CCF to gallons (748 per CCF) and, for metric forms, to cubic meters (about 2.83 per CCF).
- Compute intensity. Divide monthly use by occupied room-nights. The hotel water benchmark does this from your rooms, occupancy and bills, and splits the total by end use with EPA’s hotel shares. For the fictional Pearlbank Hotel it gives about 147 gallons per occupied room-night.
- Inventory fixtures. List every showerhead, faucet, toilet and urinal with its rated flow and whether it is WaterSense labeled. Measure a sample with a bucket and a stopwatch, the quick method FEMP describes, and keep the results with dates.
- Write the leak routine. Set check frequencies by area, give housekeeping a way to report, and keep an incident log with date found and date fixed.
- Add meters where the water goes. Laundry, irrigation and any cooling tower are the usual candidates. Read every meter at least weekly if you are aiming at LEED’s submeter point.
- Draft the plan. Follow FEMP’s seven steps, set one or two water targets per guest night, and name who reviews progress each quarter.
- Review Legionella risk if the property has a hot tub, cooling tower or fountain, or plans a reuse tank.
Five mistakes that cost points
- Reading the wrong criteria. FEE publishes separate 2022 to 2026 and 2026 to 2031 criteria, Green Key Global’s Eco-Rating is a different program, and LEED v4.1 and v5 score water by different methods.
- Assuming “standard” means efficient. A 2.5 gallon per minute showerhead meets Green Seal’s limit but not Green Key’s 9 liters or LEED v5’s 2.0 gallon prescriptive cap.
- Reusing water without a meter. LEED v5 requires alternative water to be metered separately, and Green Key recommends a meter on rain and condensate systems.
- Fixing leaks without a record. Green Key’s auditor asks for the incident log, not only for dry fixtures on the day of the visit.
- Relying on an ended program. EPA’s H2Otel Challenge is no longer active, even where older guides still suggest joining it.
Maredes is a Jackson, Mississippi company that designs water treatment and reuse systems for one building at a time. A Maredes water review produces a written water balance from your bills, meters and fixtures, with findings in order of cost; that is the same raw material these programs ask for, though no program has reviewed or endorsed it. The hotels page shows how laundry recycling and condensate capture fit a hotel, and monitoring and service covers the readings and maintenance log that keep a reuse system’s numbers reportable. More articles for hotel and apartment owners are in the hotels and apartments section. To ask a question about your property, contact Maredes.