Maredes homeRequest a water review
Menu

Greywater calculator: supply against toilet flushing

Showers and bathroom sinks on one side, toilets on the other. See whether a building makes enough greywater to cover its flushing.

For: Owners and managers of hotels, apartment buildings and dormitories, and builders

A round chrome shower head above the waterline releases a fine spray of drops that enter the surface and continue below as a slow column of bubbles.

Calculator

Example values are filled in (the fictional Pearlbank Hotel at 70 percent occupancy, about 134 guests, with planning assumptions for each guest). Replace them with your own; results update as you type. Nothing you enter leaves your browser.

Enter 0 if laundry water goes to a separate laundry recycling system or to the sewer.

Results

Greywater collected and treated per day
2,291 gal
Toilet flushing demand per day
858 gal
Share of flushing greywater can cover
100%
City water still needed for flushing per day
0 gal
Greywater left over per day (to sewer or irrigation)
1,434 gal
City water saved per year
313,024 gal
Storage for one day of flushing demand
858 gal

Greywater is collected from showers, baths, bathroom sinks and, where allowed, clothes washers; kitchen sinks and toilets are excluded. EPA advises using untreated greywater within 24 hours; greywater stored longer or used indoors is treated and disinfected first, and its piping is labeled and kept separate from drinking water with backflow protection. Local code and the health department decide what is allowed.

This calculator compares two daily volumes in one building: the greywater its showers, baths and bathroom sinks produce, and the water its toilets flush. If the first is larger, treated greywater could in principle cover all the flushing. It is for owners and managers of hotels, apartment buildings and dormitories who are weighing greywater recycling, and for builders deciding whether to plan separate piping.

EPA defines greywater as wastewater “from lavatory sinks, laundries, and bathing.” It never contains water from toilets or urinals and excludes kitchen sinks. That definition sets what the calculator counts.

How the calculator works

  • Greywater collected and treated per day = people x (shower and bath + bathroom sink + laundry gallons per person) x (1 minus the treatment loss).
  • Toilet flushing demand per day = people x flushes per person x gallons per flush.
  • Used is the smaller of the two. The share covered is used divided by demand; city water still needed is demand minus used; the leftover is supply minus used.
  • City water saved per year = used x 365.
  • Storage for one day of flushing equals the daily demand.

The inputs and where to find them

  • People on an average day. Residents for apartments; occupied rooms times guests per room for a hotel; staff on a normal day for an office.
  • Shower and bath water per person. Shower minutes times showerhead flow. Standard showerheads use 2.5 gallons per minute and WaterSense labeled models no more than 2.0 (EPA), so 16 gallons is, for example, an 8-minute shower at 2.0.
  • Bathroom sink water per person. Minutes at the sink times faucet flow; 3 gallons is an assumption.
  • Laundry water per person, if collected. Enter 0 if laundry water goes to a separate laundry recycling system or to the sewer.
  • Flushes and gallons per flush. From the toilet label: 1.6 for the federal standard, 1.28 or less for WaterSense models (EPA). Urinals use less water per flush; where there are many, run the calculator for them separately.
  • Treatment loss. Backwash, overflow and other water the unit sends to drain. Ask the maker; 10 percent is a planning assumption.

The default example

Example (fictional). The Pearlbank Hotel is a fictional 96-room hotel at 70 percent occupancy: about 67 occupied rooms with two guests each, 134 people. Each guest is assumed to use 16 gallons in the shower and 3 at the sink and to flush 5 times at 1.28 gallons. Laundry is 0 because the hotel’s laundry water goes to a separate rinse recycling system. With a 10 percent treatment loss the calculator returns: greywater collected and treated per day 2,291 gal; toilet flushing demand per day 858 gal; share of flushing greywater can cover 100%; city water still needed for flushing per day 0 gal; greywater left over per day 1,434 gal; city water saved per year 313,024 gal; storage for one day of flushing demand 858 gal.

On paper the hotel makes more than two and a half times the greywater its toilets need. In the fictional example project, greywater for flushing was still screened out: the existing building has no separate drain and supply piping, and adding both would mean new pipe runs through occupied guest floors. The Department of Energy notes that dual plumbing is easier in new construction. The plan uses laundry rinse recycling and a rain and condensate tank instead. The balance is necessary, but the building decides.

Reading the result

  • 100 percent covered with water left over: size treatment and storage to the flushing demand, not the supply. The leftover goes to the sewer, or to subsurface irrigation where the local authority allows it.
  • Below 100 percent: the toilets still need city water as makeup, supplied through an air gap or a backflow preventer.
  • Storage: about one day of flushing demand. EPA says untreated greywater should be used within 24 hours and recommends disinfection for all water used indoors for toilet flushing.
  • Flushes per person: five per guest may be high for a hotel where guests are out all day, while staff and lobby restrooms add flushes the guest count misses. Try lower and higher values.

Limits and next steps

Mississippi has no state greywater rule. It is not among the 12 states EPA lists with onsite non-potable reuse regulations or guidelines, and a search of MSDH’s on-site wastewater regulations found no greywater provisions. Approval is decided project by project by the local building official and, where wastewater is involved, the health department; EPA advises consulting local health officials first. Maredes writes a code path memo for every reuse design.

Equipment is limited too. NSF/ANSI 350 covers onsite reuse treatment, with Class R for single-family homes and Class C for multifamily and commercial buildings. On November 21, 2026, NSF’s listing showed greywater systems from only three makers. Maredes specifies a listed unit in the right class where the market offers one.

Next, size storage with the tank sizing calculator and price the result with the water savings calculator. For new buildings, where separate piping is easier to add, see builders and developers.

Start with a water review.

Tell us about the building: what it is, who uses it, where the water comes from and what you would like to change. We reply with questions and a time to walk the building with you.